Simultaneous electrochemical determination of epinephrine and uric acid at 1-butyl-4-methyl-pyridinium tetrafluroborate ionic liquid modified carbon paste electrode: A voltammetric study

被引:46
作者
Chandrashekar, Bannanakere N. [1 ]
Swamy, Bahaddurghatta E. Kumara [1 ]
Ashoka, Nanjappa B. [1 ]
Pandurangachar, Mundargi [2 ]
机构
[1] Kuvempu Univ, Dept PG Studies & Res Ind Chem, Shimoga 577451, Karnataka, India
[2] NMKRV Degree Coll Women Autonomous, Dept Chem, Bangalore 11, Karnataka, India
关键词
Ionic liquid; BMPTB/CPE; Epinephrine; UA; Cyclic voltammetry; Differential pulse voltammetry; ASCORBIC-ACID; DOPAMINE; ELECTROCATALYSIS; NOREPINEPHRINE; DEPOSITION; CATALYSIS; OXIDATION; SENSOR;
D O I
10.1016/j.molliq.2011.11.005
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An ionic liquid (IL) film 1-butyl-4-methyl-pyridinium tetrafluroborate modified carbon paste electrode (BMPTB/CPE) was fabricated and the electrochemical behavior of epinephrine at the modified electrode was investigated by cyclic voltammetric and differential pulse voltammetric techniques. A well-defined oxidation peak was observed at 0.21 V and the significant increase in peak current at modified carbon paste electrode compared to bare carbon paste electrode was obtained. The effect of scan rate on the oxidation of epinephrine was examined and it was found that the anodic peak current was proportional to the concentration of epinephrine in the range from 0.5 x 10(-5) to 4.5 x 10(-5) M. The BMPTB/CPE showed significantly higher sensitivity, and selectivity and used for the simultaneous determination of epinephrine and uric acid. The advantages of this biosensor showed simplicity, inherent stability and ability for simultaneous determination without using any other separation systems. The analytical performance of this biosensor has been evaluated for detection of epinephrine injection in serum as real sample. (C) 2011 Elsevier BM. All rights reserved.
引用
收藏
页码:168 / 172
页数:5
相关论文
共 34 条
[1]   Three-phase electrochemistry with a cylindrical microelectrode [J].
Bak, E ;
Donten, M ;
Stojek, Z .
ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (05) :483-489
[2]   Use of room temperature ionic liquids in gas sensor design [J].
Buzzeo, MC ;
Hardacre, C ;
Compton, RG .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :4583-4588
[3]   Electropolymerisation of L-arginine at carbon paste electrode and its application to the detection of dopamine, ascorbic and uric acid [J].
Chandrashekar, B. N. ;
Swamy, B. E. Kumara ;
Pandurangachar, M. ;
Sathisha, T. V. ;
Sherigara, B. S. .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 88 (01) :413-418
[4]  
Chandrashekar BN, 2010, INT J ELECTROCHEM SC, V5, P578
[5]   Simultaneous electrochemical determination of dopamine and ascorbic acid using poly (L-serine) modified carbon paste electrode [J].
Chitravathi, S. ;
Swamy, B. E. Kumara ;
Mamatha, G. P. ;
Sherigara, B. S. .
JOURNAL OF MOLECULAR LIQUIDS, 2011, 160 (03) :193-199
[6]  
Cull SG, 2000, BIOTECHNOL BIOENG, V69, P227
[7]  
DUTT V V S E, 1974, Analytical Chemistry, V46, P1777, DOI 10.1021/ac60348a041
[8]   Enzymatic catalysis of formation of Z-aspartame in ionic liquid -: An alternative to enzymatic catalysis in organic solvents [J].
Erbeldinger, M ;
Mesiano, AJ ;
Russell, AJ .
BIOTECHNOLOGY PROGRESS, 2000, 16 (06) :1129-1131
[9]   Post-column terbium complexation and sensitized fluorescence detection for the determination of norepinephrine, epinephrine and dopamine using high-performance liquid chromatography [J].
Fotopoulou, MA ;
Ioannou, PC .
ANALYTICA CHIMICA ACTA, 2002, 462 (02) :179-185
[10]   Enzyme-catalyzed direct electron transfer: Fundamentals and analytical applications [J].
Ghindilis, AL ;
Atanasov, P ;
Wilkins, E .
ELECTROANALYSIS, 1997, 9 (09) :661-674