Bone response to surface-modified titanium implants: Studies on the early tissue response to machined and electropolished implants with different oxide thicknesses

被引:285
作者
Larsson, C [1 ]
Thomsen, P [1 ]
Aronsson, BO [1 ]
Rodahl, M [1 ]
Lausmaa, J [1 ]
Kasemo, B [1 ]
Ericson, LE [1 ]
机构
[1] CHALMERS UNIV TECHNOL,DEPT APPL PHYS,S-41390 GOTHENBURG,SWEDEN
关键词
titanium; surface analysis; electropolishing; anodic oxidation; morphometry; bone; oxide; surface topography;
D O I
10.1016/0142-9612(96)88711-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The bone formation around titanium implants with varied surface properties is investigated. Machined and electropolished samples with and without thick, anodically formed surface oxides were prepared, surface characterized and inserted in the cortical bone of rabbits (1, 3 and 6 weeks). Scanning electron microscopy, scanning Auger electron spectroscopy and atomic force microscopy revealed marked differences in oxide thickness, surface topography and roughness, but no significant differences in surface chemical composition, between the different groups of implants. Light microscopic morphology and morphometry showed that all implants were in contact with bone and had a large proportion of bone within the threads at 6 weeks. The smooth, electropolished implants, irrespective of anodic oxidation, were surrounded by less bone than the machined implants after 1 week. After 6 weeks the bone volume as well as the bone-implant contact were lower for the merely electropolished implants than for the other three groups. Our study shows that a high degree of bone contact and bone formation are achieved with titanium implants which are modified with respect to oxide thickness and surface topography. However, the result with the smooth (electropolished) implants indicates that a reduction of surface roughness, in the initial phase, decreases the rate of bone formation in rabbit cortical bone.
引用
收藏
页码:605 / 616
页数:12
相关论文
共 53 条
[1]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
[2]   THE INTERFACE ZONE OF INORGANIC IMPLANTS INVIVO - TITANIUM IMPLANTS IN BONE [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
KASEMO, B ;
LARSSON, K ;
LUNDSTROM, I ;
MCQUEEN, DH ;
SKALAK, R .
ANNALS OF BIOMEDICAL ENGINEERING, 1983, 11 (01) :1-27
[3]   MICROSTRUCTURE AND MORPHOLOGY OF SURFACE OXIDE-FILMS ON TI-6AL-4V [J].
ASK, M ;
ROLANDER, U ;
LAUSMAA, J ;
KASEMO, B .
JOURNAL OF MATERIALS RESEARCH, 1990, 5 (08) :1662-1667
[4]  
ASK M, 1988, APPL SURF SCI, V35, P283
[5]  
BAIER RE, 1992, TISSUE INTEGRATION IN ORAL, ORTHOPEDIC, AND MAXILLOFACIAL RECONSTRUCTION, P240
[6]   CHARACTERIZATION OF SURFACE-ROUGHNESS IN TITANIUM DENTAL IMPLANTS MEASURED WITH SCANNING TUNNELING MICROSCOPY AT ATMOSPHERIC-PRESSURE [J].
BARO, AM ;
GARCIA, N ;
MIRANDA, R ;
VAZQUEZ, L ;
APARICIO, C ;
OLIVE, J ;
LAUSMAA, J .
BIOMATERIALS, 1986, 7 (06) :463-466
[7]  
Bowers K T, 1992, Int J Oral Maxillofac Implants, V7, P302
[8]  
Branemark P.I., 1985, TISSUE INTEGRATED PR
[9]   INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS [J].
BUSER, D ;
SCHENK, RK ;
STEINEMANN, S ;
FIORELLINI, JP ;
FOX, CH ;
STICH, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :889-902
[10]   EFFECTS OF A GROOVED TITANIUM-COATED IMPLANT SURFACE ON EPITHELIAL-CELL BEHAVIOR INVITRO AND INVIVO [J].
CHEHROUDI, B ;
GOULD, TRL ;
BRUNETTE, DM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (09) :1067-1085