Bone response to surface-modified titanium implants: Studies on the early tissue response to machined and electropolished implants with different oxide thicknesses

被引:285
作者
Larsson, C [1 ]
Thomsen, P [1 ]
Aronsson, BO [1 ]
Rodahl, M [1 ]
Lausmaa, J [1 ]
Kasemo, B [1 ]
Ericson, LE [1 ]
机构
[1] CHALMERS UNIV TECHNOL,DEPT APPL PHYS,S-41390 GOTHENBURG,SWEDEN
关键词
titanium; surface analysis; electropolishing; anodic oxidation; morphometry; bone; oxide; surface topography;
D O I
10.1016/0142-9612(96)88711-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The bone formation around titanium implants with varied surface properties is investigated. Machined and electropolished samples with and without thick, anodically formed surface oxides were prepared, surface characterized and inserted in the cortical bone of rabbits (1, 3 and 6 weeks). Scanning electron microscopy, scanning Auger electron spectroscopy and atomic force microscopy revealed marked differences in oxide thickness, surface topography and roughness, but no significant differences in surface chemical composition, between the different groups of implants. Light microscopic morphology and morphometry showed that all implants were in contact with bone and had a large proportion of bone within the threads at 6 weeks. The smooth, electropolished implants, irrespective of anodic oxidation, were surrounded by less bone than the machined implants after 1 week. After 6 weeks the bone volume as well as the bone-implant contact were lower for the merely electropolished implants than for the other three groups. Our study shows that a high degree of bone contact and bone formation are achieved with titanium implants which are modified with respect to oxide thickness and surface topography. However, the result with the smooth (electropolished) implants indicates that a reduction of surface roughness, in the initial phase, decreases the rate of bone formation in rabbit cortical bone.
引用
收藏
页码:605 / 616
页数:12
相关论文
共 53 条
[21]  
Kasemo B, 1985, Swed Dent J Suppl, V28, P19
[22]   BIOMATERIAL AND IMPLANT SURFACES - ON THE ROLE OF CLEANLINESS, CONTAMINATION, AND PREPARATION PROCEDURES [J].
KASEMO, B ;
LAUSMAA, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH-APPLIED BIOMATERIALS, 1988, 22 (A2) :145-158
[23]   CHARACTERIZATIONS OF TITANIUM IMPLANT SURFACES .3. [J].
KELLER, JC ;
STANFORD, CM ;
WIGHTMAN, JP ;
DRAUGHN, RA ;
ZAHARIAS, R .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (08) :939-946
[24]  
Klauber C, 1990, Int J Oral Maxillofac Implants, V5, P264
[25]  
KONONEN M, 1992, J BIOMED MATER RES, V26, P1325
[26]   FUNDAMENTAL-ASPECTS OF ELECTROPOLISHING [J].
LANDOLT, D .
ELECTROCHIMICA ACTA, 1987, 32 (01) :1-11
[27]   BONE RESPONSE TO SURFACE-MODIFIED TITANIUM IMPLANTS - STUDIES ON ELECTROPOLISHED IMPLANTS WITH DIFFERENT OXIDE THICKNESSES AND MORPHOLOGY [J].
LARSSON, C ;
THOMSEN, P ;
LAUSMAA, J ;
RODAHL, M ;
KASEMO, B ;
ERICSON, LE .
BIOMATERIALS, 1994, 15 (13) :1062-1074
[28]   A SURFACE SPECTROSCOPIC STUDY OF NITROGEN ION-IMPLANTED TI AND TI-6AL-4V WEAR AGAINST UHMWPE [J].
LAUSMAA, J ;
ROSTLUND, T ;
MCKELLOP, H .
SURFACE AND INTERFACE ANALYSIS, 1990, 15 (05) :328-336
[29]   MULTITECHNIQUE SURFACE CHARACTERIZATION OF OXIDE-FILMS ON ELECTROPOLISHED AND ANODICALLY OXIDIZED TITANIUM [J].
LAUSMAA, J ;
KASEMO, B ;
MATTSSON, H ;
ODELIUS, H .
APPLIED SURFACE SCIENCE, 1990, 45 (03) :189-200
[30]   SURFACE SPECTROSCOPIC CHARACTERIZATION OF TITANIUM IMPLANT MATERIALS [J].
LAUSMAA, J ;
KASEMO, B ;
MATTSSON, H .
APPLIED SURFACE SCIENCE, 1990, 44 (02) :133-146