Fast Data Acquisition and Analysis with Real Time Triplane Echocardiography for the Assessment of Left Ventricular Size and Function: A Validation Study

被引:19
作者
Nucifora, Gaetano [1 ]
Badano, Luigi P. [1 ]
Dall'Armellina, Erica [1 ]
Gianfagna, Pasquale [1 ]
Allocca, Giuseppe [1 ]
Fioretti, Paolo M. [1 ]
机构
[1] Univ Hosp S Maria Misericordia, Dept Cardiopulm Sci, I-33100 Udine, Italy
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2009年 / 26卷 / 01期
关键词
three-dimensional echocardiography; two-dimensional echocardiography; cardiac magnetic resonance; left ventricular function; CARDIAC MAGNETIC-RESONANCE; 3-DIMENSIONAL ECHOCARDIOGRAPHY; EJECTION FRACTION; COMPUTED-TOMOGRAPHY; ATRIAL-FIBRILLATION; VOLUMES; QUANTIFICATION; MASS;
D O I
10.1111/j.1540-8175.2008.00762.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To assess accuracy and reproducibility of real time simultaneous triplane echocardiography (RT3PE) for the assessment of left ventricular (LV) volumes and ejection fraction (EF) using cardiac magnetic resonance (CMR) as a reference method. Methods and Results: A total of 24 patients with various degrees of LV dysfunction (EF from 36 to 57%) in sinus rhythm with good image quality were enrolled in the study. Digital loops of apical views were recorded with standard two-dimensional imaging and with RT3PE. Echocardiography and CMR were performed within 1 hour. RT3PE measurements of LV end-diastolic volume, end-systolic volume, and EF resulted closely correlated to CMR (r = 0.95, 0.97, and 0.95, respectively) with small biases (-4 ml, -6 ml, and 1%, respectively) and narrow limits of agreement (SD = 15 ml, 12 ml, and 6%, respectively). Two-dimensional echocardiography (2DE) showed a weaker correlation with CMR (r = 0.85, 0.91, and 0.83, respectively; P < 0.06) with similar biases (-4 ml, -10 ml, 5%, respectively), but wider limits of agreement (SD = 28 ml, 21 ml, 10%, respectively, P < 0.007). RT3PE showed lower interobserver variability for the assessment of EF (SD = 2% vs. 5%, P = 0.03) and lower measurement time of LV EF (175 +/- 54 sec vs. 241 +/- 49 sec, respectively; P < 0.0001), as compared to 2DE. Conclusion: RT3PE allows simple and fast image acquisition and volume calculation. In addition, it allows more accurate and reproducible EF measurements than conventional 2DE. (ECHOCARDIOGRAPHY, Volume 26, January 2009).
引用
收藏
页码:66 / 75
页数:10
相关论文
共 26 条
[1]   Assessment of ventricular function and mass by cardiac magnetic resonance imaging [J].
Alfakih, K ;
Reid, S ;
Jones, T ;
Sivananthan, M .
EUROPEAN RADIOLOGY, 2004, 14 (10) :1813-1822
[2]   Real-time three-dimensional echocardiography: technological gadget or clinical tool? [J].
Badano, Luigi P. ;
Dall'Armellina, Erica ;
Monaghan, Mark J. ;
Pepi, Mauro ;
Baldassi, Mara ;
Cinello, Margherita ;
Fioretti, Paolo M. .
JOURNAL OF CARDIOVASCULAR MEDICINE, 2007, 8 (03) :144-162
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: Comparison with magnetic resonance imaging [J].
Caiani, EG ;
Corsi, C ;
Zamorano, J ;
Sugeng, L ;
MacEneaney, P ;
Weinert, L ;
Battani, R ;
Gutierrez, JL ;
Koch, R ;
de Isla, LP ;
Mor-Avi, V ;
Lang, RM .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (08) :779-788
[5]   What is the optimal clinical technique for measurement of left ventricular volume after myocardial infarction? A comparative study of 3-dimensional echocardiography, single photon emission computed tomography, and cardiac magnetic resonance imaging [J].
Chan, J ;
Jenkins, C ;
Khafagi, F ;
Du, L ;
Marwick, TH .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (02) :192-201
[6]   Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images [J].
Corsi, C ;
Lang, RM ;
Veronesi, F ;
Weinert, L ;
Caiani, EG ;
MacEneaney, P ;
Lamberti, C ;
Mor-Avi, V .
CIRCULATION, 2005, 112 (08) :1161-1170
[7]   Comparison of real-time tri-plane and conventional 2D dobutamine stress echocardiography for the assessment of coronary artery disease [J].
Eroglu, Elif ;
D'hooge, Jan ;
Herbots, Lieven ;
Thijs, Daisy ;
Dubois, Christophe ;
Sinnaeve, Peter ;
Dens, Joseph ;
Vanhaecke, Johan ;
Rademakers, Frank .
EUROPEAN HEART JOURNAL, 2006, 27 (14) :1719-1724
[8]  
Goldman R, 2004, GRAPHICS GEMS, VII, P170
[9]   Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathies [J].
Gutiérrez-Chico, JL ;
Zamorano, JL ;
de Isla, LP ;
Orejas, M ;
Almería, C ;
Rodrigo, JL ;
Ferreirós, J ;
Serra, V ;
Macaya, C .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (06) :809-813
[10]   Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data [J].
Jacobs, LD ;
Salgo, IS ;
Goonewardena, S ;
Weinert, L ;
Coon, P ;
Bardo, D ;
Gerard, O ;
Allain, P ;
Zamorano, JL ;
de Isla, LP ;
Mor-Avi, V ;
Lang, RM .
EUROPEAN HEART JOURNAL, 2006, 27 (04) :460-468