Techniques for the detection of coronary atherosclerosis: Multi-detector row CT coronary angiography

被引:144
作者
Vogl, TJ
Abolmaali, ND
Diebold, T
Engelmann, K
Ay, M
Dogan, S
Wimmer-Greinecker, G
Moritz, A
Herzog, C
机构
[1] Univ Frankfurt, Inst Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Univ Frankfurt, Dept Cardiovasc Thorac Surg, D-60590 Frankfurt, Germany
关键词
angiography; computed tomography (CT); multidetector row; three-dimensional; coronary vessels; CT; heart;
D O I
10.1148/radiol.2231010515
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the accuracy of different computed tomographic (CT) reformation techniques in assessing the coronary arteries. MATERIALS AND METHODS: Sixty-four patients undergoing both multi-detector row CT and invasive coronary angiography were consecutively included in a retrospective study. CT scans were obtained with collimation of 4 X I mm, pitch of 1.5, and rotation time of 500 msec. Retrospective electrocardiographic gating was used for image reconstruction, with 1.25-mm section thickness and 0.5-mm increment. The CT data set of each patient was evaluated by independent observers using transverse scanning, virtual endoscopic, and three-dimensional reformation and multiplanar reformation. RESULTS: Hemodynamically relevant stenoses (>50%) were detected with highest sensitivity at transverse scanning (58 of 79 [73.4%] stenoses), followed by virtual endoscopic (38 of 79 [48.1 %] stenoses) and three-dimensional reformation (34 of 79 [43.0%] stenoses), and multiplanar reformation (37 of 79 [46.8%] stenoses). Atherosclerotic plaques were identified with comparable sensitivities at transverse scanning (143 of 218 plaques [65.6%]) and at three-dimensional (139 of 218 [63.8%] plaques) and virtual endoscopic reformation (136 of 218 [62.4%] plaques). Multiplanar reformation had distinctly poorer results (217 of 218 [58.3%] plaques). Combined interpretation with all four techniques increased sensitivity to 74.7% (59 of 79) for stenosis and 71.6% (156 of 218) for atherosclerosis. Calculated overall specificity was 91.4% or greater. Sufficient vascular evaluation was possible only in vessels larger than 1.6 mm in diameter. Thus, even in patients with heart rates below 60 bpm, only 80.0% of all coronary segments could be visualized, while at higher frequencies, visibility decreased to 66.2%. CONCLUSION: Although multi-detector row CT is a favorable alternative procedure in evaluating coronary arteries, its clinical value still is restricted to low heart rates and proximal coronary arterial segments. (C) RSNA, 2002.
引用
收藏
页码:212 / 220
页数:9
相关论文
共 29 条
[1]   Comparison of vessel diameters in electron beam tomography and quantitative coronary angiography [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Bachmann, K .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (01) :1-7
[2]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[3]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[4]   Comparison of electron beam computed tomography with intracoronary ultrasound and coronary angiography for detection of coronary atherosclerosis [J].
Baumgart, D ;
Schmermund, A ;
Goerge, G ;
Haude, M ;
Ge, JB ;
Adamzik, M ;
Sehnert, C ;
Altmaier, K ;
Groenemeyer, D ;
Seibel, R ;
Erbel, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (01) :57-64
[5]  
Becker CR, 2000, RADIOLOGE, V40, P118, DOI 10.1007/s001170050019
[6]   Detection and quantification of coronary artery calcification with electron-beam and conventional CT [J].
Becker, CR ;
Knez, A ;
Jakobs, TF ;
Aydemir, S ;
Becker, A ;
Schoepf, UJ ;
Bruening, R ;
Haberl, R ;
Reiser, MF .
EUROPEAN RADIOLOGY, 1999, 9 (04) :620-624
[7]  
BECKER CR, 1999, ELEKTROMEDICA, V67, P116
[8]   Ultrafast computed tomography as a diagnostic modality in the detection of coronary artery disease: A multicenter study [J].
Budoff, MJ ;
Georgiou, D ;
Brody, A ;
Agatston, AS ;
Kennedy, J ;
Wolfkiel, C ;
Stanford, W ;
Shields, P ;
Lewis, RJ ;
Janowitz, WR ;
Rich, S ;
Brundage, BH .
CIRCULATION, 1996, 93 (05) :898-904
[9]   DISTRIBUTION OF CIRCUMFERENTIAL STRESS IN RUPTURED AND STABLE ATHEROSCLEROTIC LESIONS - A STRUCTURAL-ANALYSIS WITH HISTOPATHOLOGICAL CORRELATION [J].
CHENG, GC ;
LOREE, HM ;
KAMM, RD ;
FISHBEIN, MC ;
LEE, RT .
CIRCULATION, 1993, 87 (04) :1179-1187
[10]   OBSERVER AGREEMENT IN EVALUATING CORONARY ANGIOGRAMS [J].
DETRE, KM ;
WRIGHT, E ;
MURPHY, ML ;
TAKARO, T .
CIRCULATION, 1975, 52 (06) :979-986