Fluorescent conjugated polymer molecular wire chemosensors for transition metal ion recognition and signaling

被引:245
作者
Fan, Li-Juan [1 ,2 ]
Zhang, Yan [1 ]
Murphy, Clifford B. [1 ]
Angell, Sarah E. [1 ]
Parker, Matthew F. L. [1 ]
Flynn, Brendan R. [1 ]
Jones, Wayne E., Jr. [1 ]
机构
[1] SUNY Binghamton, Dept Chem, Binghamton, NY 13902 USA
[2] Soochow Univ, Sch Chem & Chem Engn, Suzhou 215123, Peoples R China
关键词
Fluorescent chemosensor; Conjugated polymer; Molecular wire; Electron transfer; Energy transfer; Fluorescent enhancement and quenching; PHOTOINDUCED ELECTRON-TRANSFER; CHELATION-ENHANCED FLUORESCENCE; CHEMICAL SENSORS; ENERGY MIGRATION; SIDE-CHAINS; DESIGN; LIGHT; DERIVATIVES; BIOSENSORS; PHOTOLUMINESCENCE;
D O I
10.1016/j.ccr.2008.03.008
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Conjugated polymer molecular wires have advantages over small molecules for sensing applications due to enhancements associated with electronic communication along the polymer backbone. The majority of examples from the literature focus on fluorescence "turn-off" as the mechanism of sensor response. The energy transfer mechanism involved in these polymers focuses on energy transfer quenching and can be related to either a Dexter or Forster based mechanism. More recently, a series of chemosensors have been designed and synthesized which exhibit fluorescence "turn-on" behavior upon binding specific cations. The general assembly of both the turn-on and turn-off chemosensor Structures involves assembling different organic receptor ligands onto the conjugated polymer backbones. Careful spectroscopic analysis of the energy and electron transfer mechanisms in these systems creates a myriad of opportunities for the design of new sensor materials. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:410 / 422
页数:13
相关论文
共 103 条
[41]  
Guillet J., 1985, Polymer Photophysics and Photochemistry. An Introduction to the Study of Photoprocesses in Macromolecules
[42]   Anion recognition and sensing in organic and aqueous media using luminescent and colorimetric sensors [J].
Gunnlaugsson, Thorfinnur ;
Glynn, Mark ;
Tocci , Gillian M. ;
Kruger, Paul E. ;
Pfeffer, Frederick M. .
COORDINATION CHEMISTRY REVIEWS, 2006, 250 (23-24) :3094-3117
[43]  
Harris D.C., 1999, Quantitative Chemical Analysis, V5th
[44]  
Harsanyi G., 2000, In Sensors in biomedical applications: fundamentals, technology applications
[45]   Optical sensors based on hybrid aptamer/conjugated polymer complexes [J].
Ho, HA ;
Leclerc, M .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (05) :1384-1387
[46]  
Ho HA, 2002, ANGEW CHEM INT EDIT, V41, P1548, DOI 10.1002/1521-3773(20020503)41:9<1548::AID-ANIE1548>3.0.CO
[47]  
2-I
[48]   CHELATION-ENHANCED FLUORESCENCE IN 9,10-BIS(TMEDA)ANTHRACENE [J].
HUSTON, ME ;
HAIDER, KW ;
CZARNIK, AW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (13) :4460-4462
[49]   CHELATION ENHANCED FLUORESCENCE DETECTION OF NON-METAL IONS [J].
HUSTON, ME ;
AKKAYA, EU ;
CZARNIK, AW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (23) :8735-8737
[50]   ON THE LIMITATION OF COMPARATIVE QUENCHING AS A MEASURE OF ELECTRONIC-ENERGY TRANSFER IN POLYMERS [J].
ITOH, Y ;
KAMIOKA, K ;
WEBBER, SE .
MACROMOLECULES, 1989, 22 (06) :2851-2852