SPASM:: A 3D-ASM for segmentation of sparse and arbitrarily oriented cardiac MRI data

被引:154
作者
van Assen, HC
Danilouchkine, MG
Frangi, AF
Ordás, S
Westenberg, JJM
Reiber, JHC
Lelieveldt, BR
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc, NL-2300 RC Leiden, Netherlands
[2] Univ Pompeu Fabra, Dept Technol, Computat Imaging Lab, Barcelona, Spain
关键词
SPASM; active shape model; ASM; 3D; sparse; MRI; CT; segmentation; cardiac; short-axis; SA; long-axis; LA; radial;
D O I
10.1016/j.media.2005.12.001
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A new technique (SPASM) based on a 3D-ASM is presented for automatic segmentation of cardiac MRI image data sets consisting of multiple planes with arbitrary orientations, and with large undersampled regions. Model landmark positions are updated in a two-stage iterative process. First, landmark positions close to intersections with images are updated. Second, the update information is propagated to the regions without image information, such that new locations for the whole set of the model landmarks are obtained. Feature point detection is performed by a fuzzy inference system, based on fuzzy C-means clustering. Model parameters were optimized on a computer cluster and the computational load distributed by grid computing. SPASM was applied to image data sets with an increasing sparsity (from 2 to 11 slices) comprising images with different orientations and stemming from different MRI acquisition protocols. Segmentation outcomes and calculated volumes were compared to manual segmentation on a dense short-axis data configuration in a 3D manner. For all data configurations, (sub-)pixel accuracy was achieved. Performance differences between data configurations were significantly different (p<0.05) for SA data sets with less than 6 slices, but not clinically relevant (volume differences <4 ml). Comparison to results from other 3D model-based methods showed that SPASM performs comparable to or better than these other methods, but SPASM uses considerably less image data. Sensitivity to initial model placement proved to be limited within a range of position perturbations of approximately 20 mm in all directions. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:286 / 303
页数:18
相关论文
共 37 条
[1]  
[Anonymous], Pattern Recognition With Fuzzy Objective Function Algorithms
[2]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[3]   Automated registration of dynamic MR images for the quantification of myocardial perfusion [J].
Bidaut, LM ;
Vallée, JP .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :648-655
[4]   Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle [J].
Bloomer, TN ;
Plein, S ;
Radjenovic, A ;
Higgins, DM ;
Jones, TR ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (06) :685-692
[5]  
Chandrashekara R, 2003, LECT NOTES COMPUT SC, V2732, P599
[6]  
Cootes T. F., 2004, STAT MODELS APPEARAN
[7]   TRAINABLE METHOD OF PARAMETRIC SHAPE-DESCRIPTION [J].
COOTES, TF ;
COOPER, DH ;
TAYLOR, CJ ;
GRAHAM, J .
IMAGE AND VISION COMPUTING, 1992, 10 (05) :289-294
[8]   ACTIVE SHAPE MODELS - THEIR TRAINING AND APPLICATION [J].
COOTES, TF ;
TAYLOR, CJ ;
COOPER, DH ;
GRAHAM, J .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1995, 61 (01) :38-59
[9]   Active appearance models [J].
Cootes, TF ;
Edwards, GJ ;
Taylor, CJ .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2001, 23 (06) :681-685
[10]   Accuracy of short-axis cardiac MRI automatically derived from scout acquisitions in free-breathing and breath-holding modes [J].
Danilouchkine, MG ;
Westenberg, JJM ;
Reiber, JHC ;
Lelieveldt, BPF .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2005, 18 (01) :7-18