A simple approach to uncertainty propagation in preprocessed multivariate calibration

被引:31
作者
Olivieri, AC [1 ]
机构
[1] Univ Nacl Rosario, Fac Ciencias Bioquim & Farmaceut, Dept Quim Analit, RA-2000 Rosario, Argentina
关键词
multivariate calibration; orthogonal signal correction; net analyte preprocessing; uncertainty propagation; concentration variances;
D O I
10.1002/cem.716
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A simple approach is described to estimate the confidence limit for the concentrations predicted by multivariate calibration when preprocessing techniques such as orthogonal signal correction or net analyte calculation are applied. It involves reconstructing the unpreprocessed data using the extracted spectral factors and those employed for prediction in order to correctly estimate the sample leverages. Monte Carlo simulations carried out by adding random noise to both concentrations and analytical signals for theoretical binary mixtures are in excellent agreement with the calculations. Experimental multicomponent examples were studied by a similar Monte Carlo approach, and the obtained variances are also in agreement with the calculated values. Implications concerning the limits of detection in the latter cases are also discussed. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:207 / 217
页数:11
相关论文
共 43 条
[21]   Comparison of two recently proposed expressions for partial least squares regression prediction error [J].
Faber, NM .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 52 (02) :123-134
[22]  
Faber NM, 2000, J CHEMOMETR, V14, P363, DOI 10.1002/1099-128X(200007/08)14:4<363::AID-CEM580>3.3.CO
[23]  
2-Z
[24]   On orthogonal signal correction [J].
Fearn, T .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 50 (01) :47-52
[25]   A comparison of orthogonal signal correction and net analyte preprocessing methods. Theoretical and experimental study [J].
Goicoechea, HC ;
Olivieri, AC .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2001, 56 (02) :73-81
[26]   Enhanced synchronous spectrofluorometric determination of tetracycline in blood serum by chemometric analysis. Comparison of partial least-squares and hybrid linear analysis calibrations [J].
Goicoechea, HC ;
Olivieri, AC .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4361-4368
[27]   Determination of bromhexine in cough-cold syrups by absorption spectrophotometry and multivariate calibration using partial least-squares and hybrid linear analyses. Application of a novel method of wavelength selection [J].
Goicoechea, HC ;
Olivieri, AC .
TALANTA, 1999, 49 (04) :793-800
[28]   ESTIMATION OF PREDICTION ERROR FOR SAMPLES WITHIN THE CALIBRATION RANGE [J].
KARSTANG, TV ;
TOFT, J ;
KVALHEIM, OM .
JOURNAL OF CHEMOMETRICS, 1992, 6 (04) :177-188
[29]   ASSESSMENT OF THE QUALITY OF LATENT VARIABLE CALIBRATIONS BASED ON MONTE-CARLO SIMULATIONS [J].
KELLER, HR ;
ROTTELE, J ;
BARTELS, H .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :937-943
[30]   BOOTSTRAP TECHNOLOGY AND APPLICATIONS [J].
LEGER, C ;
POLITIS, DN ;
ROMANO, JP .
TECHNOMETRICS, 1992, 34 (04) :378-398