The relative contributions of different skin layers to the mechanical behavior of human skin in vivo using suction experiments

被引:257
作者
Hendriks, FM
Brokken, D
Oomens, CWJ
Bader, DL
Baaijens, FPT
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[2] Philips Res Labs, Personal Care Inst, Eindhoven, Netherlands
[3] Queen Mary Univ London, Dept Engn, London E1 4NS, England
[4] Queen Mary Univ London, Interdisciplinary Res Ctr Biomed Mat, London E1 4NS, England
关键词
epidermis; dermis; optical coherence tomography; ultrasound; finite element model;
D O I
10.1016/j.medengphy.2005.07.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Although the mechanical behavior of the top layer of the skin, the epidermis, is an important consideration in several clinical and cosmetic applications, there are few reported studies on this layer. The in vivo mechanical behavior of the upper skin layer (here defined as epidermis and papillar dermis) was characterized using a combined experimental and modeling approach. The work was based on the hypothesis that experiments with different length scales represent the mechanical behavior of different skin layers. Suction measurements with aperture diameters of 1, 2 and 6 mm were combined with ultrasound and optical coherence tomography to study the deformation of the skin layers. The experiments were simulated for small displacements with a two-layered finite element model representing the upper layer and the reticular dermis. An identification method compared the experimental and numerical results to identify the material parameters of the model. For one subject the whole parameter estimation procedure was completed, leading to a stiffness of C-10.mu l = 0.11 kPa for the top-layer and C-10.rd = 0.16 MPa for the reticular dermis. This unexpected, extreme stiffness ratio of the material parameters let to convergence problems of the finite element software for most of the individuals. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 20 条
[1]
MECHANICAL-PROPERTIES AND YOUNGS MODULUS OF HUMAN-SKIN INVIVO [J].
AGACHE, PG ;
MONNEUR, C ;
LEVEQUE, JL ;
DERIGAL, J .
ARCHIVES OF DERMATOLOGICAL RESEARCH, 1980, 269 (03) :221-232
[2]
[Anonymous], 2000, ENG GUIDE MATLAB
[3]
Barel AO, 1995, HDB NONINVASIVE METH, V106, P335
[4]
Coleman T., 1999, OPTIMIZATION TOOLBOX, Vthird
[5]
Diridollou S., 2000, International Journal of Cosmetic Science, V22, P421, DOI 10.1046/j.1467-2494.2000.00037.x
[6]
A numerical-experimental method to characterize the non-linear mechanical behaviour of human skin [J].
Hendriks, FM ;
Brokken, D ;
van Eemeren, JTWM ;
Oomens, CWJ ;
Baaijens, FPT ;
Horsten, JBAM .
SKIN RESEARCH AND TECHNOLOGY, 2003, 9 (03) :274-283
[7]
Influence of hydration and experimental length scale on the mechanical response of human skin in vivo, using optical coherence tomography [J].
Hendriks, FM ;
Brokken, D ;
Oomens, CWJ ;
Baaijens, FPT .
SKIN RESEARCH AND TECHNOLOGY, 2004, 10 (04) :231-241
[9]
OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[10]
LENDERINK E, 2002, SPIES BIOS, P121