Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode

被引:32
作者
Dominguez-Renedo, Olga [1 ]
Gomez Gonzalez, M. Jesus [1 ]
Julia Arcos-Martinez, M. [1 ]
机构
[1] Univ Burgos, Dept Quim, Area Quim Analit, Fac Ciencias, E-09001 Burgos, Spain
关键词
antimony; anodic stripping voltammetry; mercury film electrode; screen-printed; ATOMIC-ABSORPTION-SPECTROMETRY; TRACE DETERMINATION; POTENTIOMETRIC DETERMINATION; PARTICULATE MATTER; L-CYSTEINE; COPPER; SEAWATER; BISMUTH; METALS; WATERS;
D O I
10.3390/s90100219
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a procedure for the determination of antimony (III) by differential pulse anodic stripping voltammetry using a mercury film screen-printed electrode as the working electrode. The procedure has been optimized using experimental design methodology. Under these conditions, in terms of Residual Standard Deviation (RSD), the repeatability (3.81 %) and the reproducibility (5.07 %) of the constructed electrodes were both analyzed. The detection limit for Sb ( III) was calculated at a value of 1.27x10(-8) M. The linear range obtained was between 0.99 x 10(-8) - 8.26 x 10(-8) M. An analysis of possible effects due to the presence of foreign ions in the solution was performed and the procedure was successfully applied to the determination of antimony levels in pharmaceutical preparations and sea water samples.
引用
收藏
页码:219 / 231
页数:13
相关论文
共 46 条
  • [1] Anodic stripping potentiometric determination of antimony on a combined electrode
    Adeloju, SB
    Young, TM
    Jagner, D
    Batley, GE
    [J]. ANALYST, 1998, 123 (09) : 1871 - 1874
  • [2] ANODIC-STRIPPING POTENTIOMETRIC DETERMINATION OF ANTIMONY IN ENVIRONMENTAL MATERIALS
    ADELOJU, SB
    YOUNG, TM
    [J]. ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) : 225 - 232
  • [3] [Anonymous], 1998, HDB CHEMOMETRICS Q A
  • [4] BATLEY GE, 1974, J ELECTROANAL CHEM, V55, P23, DOI 10.1016/0368-1874(74)87108-X
  • [5] Development of a portable electroanalytical system for the stripping voltammetry of metals: Determination of copper in acetic acid soil extracts
    Beni, V
    Ogurtsov, VI
    Bakunin, NV
    Arrigan, DWM
    Hill, M
    [J]. ANALYTICA CHIMICA ACTA, 2005, 552 (1-2) : 190 - 200
  • [6] Combined use of differential pulse adsorptive and anodic stripping techniques for the determination of antimony(III) and antimony(V) in zinc electrolyte
    Bond, AM
    Kratsis, S
    Newman, OMG
    [J]. ANALYTICA CHIMICA ACTA, 1998, 372 (03) : 307 - 314
  • [7] DETERMINATION OF ANTIMONY IN SEAWATER BY CATHODIC STRIPPING VOLTAMMETRY
    CAPODAGLIO, G
    VAN DEN BERG, CMG
    SCARPONI, G
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 235 (1-2) : 275 - 286
  • [8] Screen-printed anodic stripping voltammetric sensor containing HgO for heavy metal analysis
    Choi, JY
    Seo, K
    Cho, SR
    Oh, JR
    Kahng, SH
    Park, J
    [J]. ANALYTICA CHIMICA ACTA, 2001, 443 (02) : 241 - 247
  • [9] APPLICABILITY OF ANODIC-STRIPPING VOLTAMMETRY AND GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY TO THE DETERMINATION OF ANTIMONY IN BIOLOGICAL MATRICES - A COMPARATIVE-STUDY
    COSTANTINI, S
    GIORDANO, R
    RIZZICA, M
    BENEDETTI, F
    [J]. ANALYST, 1985, 110 (11) : 1355 - 1359
  • [10] An environmental monitoring system for trace metals using stripping voltammetry
    Desmond, D
    Lane, B
    Alderman, J
    Hill, M
    Arrigan, DWM
    Glennon, JD
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1998, 48 (1-3) : 409 - 414