A dual-trap design and its applications in electrospray ionization FTICR mass spectrometry

被引:12
作者
Gorshkov, MV [1 ]
PasaTolic, L [1 ]
Bruce, JE [1 ]
Anderson, GA [1 ]
Smith, RD [1 ]
机构
[1] PACIFIC NW NATL LAB,ENVIRONM MOL SCI LAB,RICHLAND,WA 99352
关键词
D O I
10.1021/ac960941n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new arrangement consisting of two separate Fourier transform ion cyclotron resonance (FTICR) ion traps was used to develop methods for the manipulation of the ions produced by an electrospray ionization source (ESI). A first, ''accumulation'' trap, is generally maintained at a higher pressure than the second, high-performance ''analyzer'' trap. The manipulations developed and demonstrated include the following: (1) mass-selective ion transfers between the traps; (2) mass-selective step-wise accumulation of low-abundance ions of different mass-to-charge ratios transferred from the first trap to the analyzer trap; (3) simultaneous detection of ions in the analyzer trap and ion accumulation in the source trap; (4) simultaneous ion detection in the accumulation trap and ion storage in the analyzer trap; (5) sequential multiple transfers of the ions into the analyzer trap from the same ion population stored in the accumulation trap; (6) collision-induced dissociation of ions stored in the accumulation trap followed by mass-selective transfer of the product ions into the analyzer trap; (7) sequential transfer of the ions of different mass-to-charge ratios into the analyzer trap from the same ion population stored in the accumulation trap followed by the collision-induced dissociation of transferred ions in the analyzer trap. These ion manipulations benefit multistage studies and are projected to be useful in many biochemical applications of ESI-FTICR, including structural determination of biopolymers and study of noncovalent complexes.
引用
收藏
页码:1307 / 1314
页数:8
相关论文
共 22 条
[1]   FOURIER-TRANSFORM ELECTROSPRAY INSTRUMENTATION FOR TANDEM HIGH-RESOLUTION MASS-SPECTROMETRY OF LARGE MOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
WAMPLER, FM ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :557-565
[2]   THE ACCURACY OF HEAVY-ION MASS MEASUREMENTS USING TIME OF FLIGHT-ION CYCLOTRON-RESONANCE IN A PENNING TRAP [J].
BOLLEN, G ;
MOORE, RB ;
SAVARD, G ;
STOLZENBERG, H .
JOURNAL OF APPLIED PHYSICS, 1990, 68 (09) :4355-4374
[3]   ''Colored'' noise waveforms and quadrupole excitation for the dynamic range expansion of Fourier transform ion cyclotron resonance mass spectrometry [J].
Bruce, JE ;
Anderson, GA ;
Smith, RD .
ANALYTICAL CHEMISTRY, 1996, 68 (03) :534-541
[4]   SELECTED-ION ACCUMULATION FROM AN EXTERNAL ELECTROSPRAY-IONIZATION SOURCE WITH A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER [J].
BRUCE, JE ;
ANDERSON, GA ;
HOFSTADLER, SA ;
VANORDEN, SL ;
SHERMAN, MS ;
ROCKWOOD, AL ;
SMITH, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (10) :914-919
[5]  
CHEN R, 1995, P 43 ASMS C MASS SPE, P801
[6]   FREQUENCY-SWEEP FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISARO.MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 26 (04) :489-490
[7]   FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISAROW, MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 25 (02) :282-283
[8]   MASS DISCRIMINATION BASED ON LONGITUDINAL ION MOTION IN A DOUBLE-CELL FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER [J].
GIANCASPRO, C ;
VERDUN, FR .
ANALYTICAL CHEMISTRY, 1986, 58 (09) :2097-2099
[9]   BLOCH EQUATIONS APPLIED TO ION-CYCLOTRON RESONANCE SPECTROSCOPY - BROAD-BAND INTERCONVERSION BETWEEN MAGNETRON AND CYCLOTRON MOTION FOR ION AXIALIZATION [J].
GUAN, SH ;
MARSHALL, AG .
JOURNAL OF CHEMICAL PHYSICS, 1993, 98 (06) :4486-4493
[10]  
GUAN SH, 1994, Z CHEM REVS, V94, P2161