Development and validation of a one-step immunoassay for determination of cadmium in human serum

被引:92
作者
Darwish, IA
Blake, DA
机构
[1] Tulane Univ, Hlth Sci Ctr, Dept Ophthalmol, New Orleans, LA 70112 USA
[2] Tulane Xavier Ctr Bioenvironm Res, New Orleans, LA 70112 USA
关键词
D O I
10.1021/ac010510r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and simple one-step immunoassay was developed and validated for quantitative determination of Cd(II) in human serum. In this method, a monoclonal antibody that recognizes Cd(II)-EDTA complexes was directly immobilized onto microwell plates. The serum sample containing metallothionein(MT)-bound and non-MT-bound Cd(II) was acidified to displace the Cd(II) from MT. The sample was then treated with metal-free EDTA to convert Cd(II) to Cd(II)-EDTA complexes. A mixture of Cd(II)-EDTA complexes derived from serum samples and Cd(II)-EDTA conjugated with peroxidase enzyme was incubated in the wells to compete for binding sites of the immobilized antibody. After addition of peroxidase substrate, the bound fraction of the enzyme conjugate was measured by a microplate reader, and the signal was inversely proportional to the concentration of the Cd(II) in the sample. The assay limit of detection was 0.24 mug/L, and the effective working range at coefficient of variation of less than or equal to10% was 0.24-100 mug/L. Analytical recovery of spiked Cd(H), in the concentration range between 0.8 and 50 mug/L, was 97.8 +/- 4.0%. The assay was selective for Cd(II); other metal ions (Mn, Co, Cu, Zn, Mg, Hg, Ca, Ni, Fe, and Pb), tested at concentrations considerably higher than those present in human serum, did not significantly interfere with the assay. The assay results correlated well with those obtained by graphite furnace atomic absorption spectrometry (r = 0.984).
引用
收藏
页码:52 / 58
页数:7
相关论文
共 46 条
  • [11] Fels LM, 1999, RENAL FAILURE, V21, P275
  • [12] Simultaneous measurement of the trace elements Al, As, B, Be, Cd, Co, Cu, Fe, Li, Mn, Mo, Ni, Rb, Se, Sr, and Zn in human serum and their reference ranges by ICP-MS
    Forrer, R
    Gautschi, K
    Lutz, H
    [J]. BIOLOGICAL TRACE ELEMENT RESEARCH, 2001, 80 (01) : 77 - 93
  • [13] FRIBERG L, 1986, CADMIUM HLTH TOXICOL
  • [14] Friberg L., 1986, Handbook of the Toxicology of Metals, VII, P130
  • [15] REACTION OF CD-111(7)-METALLOTHIONEIN WITH EDTA - A REAPPRAISAL
    GAN, T
    MUNOZ, A
    SHAW, CF
    PETERING, DH
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 1995, 270 (10) : 5339 - 5345
  • [16] HYDROGEN ION BUFFERS FOR BIOLOGICAL RESEARCH
    GOOD, NE
    WINGET, GD
    WINTER, W
    CONNOLLY, TN
    IZAWA, S
    SINGH, RMM
    [J]. BIOCHEMISTRY, 1966, 5 (02) : 467 - &
  • [17] GRUBB A, 1992, CLIN NEPHROL, V38, pS20
  • [18] Environmental exposure of the pediatric age groups in Cairo City and its suburbs to cadmium pollution
    Hossny, E
    Mokhtar, G
    El-Awady, M
    ALi, I
    Morsy, M
    Dawood, A
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 273 (1-3) : 135 - 146
  • [19] Normal liver function in women in the general Japanese population subjected to environmental exposure to cadmium at various levels
    Ikeda, M
    Zhang, ZW
    Moon, CS
    Shimbo, S
    Watanabe, T
    Nakatsuka, H
    Matsuda-Inoguchi, N
    Higashikawa, K
    [J]. INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2000, 73 (02) : 86 - 90
  • [20] Jarup L, 1997, SCAND J WORK ENV HEA, V23, P31