Retention index thresholds for compound matching in GC-MS metabolite profiling

被引:124
作者
Strehmel, Nadine [1 ]
Hummel, Jan [1 ]
Erban, Alexander [1 ]
Strassburg, Katrin [1 ]
Kopka, Joachim [1 ]
机构
[1] Max Planck Inst Mol Plant Physiol, Dept Prof L Willmitzer, D-14476 Potsdam, Germany
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 871卷 / 02期
关键词
retention index matching; gas chromatography; GC-MS; metabolite profiling; metabolomics;
D O I
10.1016/j.jchromb.2008.04.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The generation of retention index (RI) libraries is an expensive and time-consuming effort. Procedures for the transfer of RI properties between chromatography variants are, therefore, highly relevant for a shared use. The precision of RI determination and accuracy of RI transfer between 8 method variants employing 5%-phenyl-95%-dimethylpolysiloxane capillary columns was investigated using a series of 9 n-alkanes (C-10-C-3G). The precision of the RI determination of 13 exemplary fatty acid methyl esters (C-8 ME-C-30 ME) was 0.22-0.33 standard deviation (S.D.) expressed in RI units in low complexity samples. In the presence of complex biological matrices this precision may deteriorate to 0.75-1.11. Application of the previously proposed Kovats, van den Dool or 3rd-5th order polynomial regression algorithms resulted in similar precision of RI calculation. For transfer of empirical van den Dool-RI properties between the chromatography variants 3rd order regression was found to represent the minimal necessary assumption. The range of typical regression coefficients was r(2) = 0.9988-0.9998 and accuracy of RI prediction between chromatography variants varied between 5.1 and 19.8 (0.29-0.69%) S.D. of residual RI error, RIpredicted - RIdetermined (n > 64). Accuracy of prediction was enhanced when subsets of chemically similar Compound classes were used for regression, for example organic acids and sugars exhibited 0.78 (n = 29) and 3.74 (n = 37) S.D. of residual RI error, respectively. In conclusion, we suggest use of percent RI error rather than absolute RI units for the definition of matching thresholds. Thresholds of 0.5-1.0% may apply to most transfers between chromatography variants. These thresholds will not solve all matching ambiguities in complex samples. Therefore, we recommend co-analysis of reference substances with each GC-MS profiling experiment. Composition of these defined reference mixtures may best approximate or mimic the quantitative and qualitative composition of the biological matrix under investigation. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:182 / 190
页数:9
相关论文
共 36 条
[1]   The critical evaluation of a comprehensive mass spectral library [J].
Ausloos, P ;
Clifton, CL ;
Lias, SG ;
Mikaya, AI ;
Stein, SE ;
Tchekhovskoi, DV ;
Sparkman, OD ;
Zaikin, V ;
Zhu, D .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (04) :287-299
[2]   Development of a database of gas chromatographic retention properties of organic compounds [J].
Babushok, V. I. ;
Linstrom, P. J. ;
Reed, J. J. ;
Zenkevich, I. G. ;
Brown, R. L. ;
Mallard, W. G. ;
Stein, S. E. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :414-421
[3]   Comprehensive metabolite profiling of Sinorhizobium meliloti using gas chromatography-mass spectrometry [J].
Barsch, A. ;
Patschkowski, T. ;
Niehaus, K. .
FUNCTIONAL & INTEGRATIVE GENOMICS, 2004, 4 (04) :219-230
[4]   Retention indices in the analysis of food aroma volatile compounds in temperature-programmed gas chromatography: Database creation and evaluation of precision and robustness [J].
Bianchi, Federica ;
Careri, Maria ;
Mangia, Alessandro ;
Musci, Marilena .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (04) :563-572
[5]   Potential of metabolomics as a functional genomics tool [J].
Bino, RJ ;
Hall, RD ;
Fiehn, O ;
Kopka, J ;
Saito, K ;
Draper, J ;
Nikolau, BJ ;
Mendes, P ;
Roessner-Tunali, U ;
Beale, MH ;
Trethewey, RN ;
Lange, BM ;
Wurtele, ES ;
Sumner, LW .
TRENDS IN PLANT SCIENCE, 2004, 9 (09) :418-425
[6]   Metabolomics Standards Workshop and the development of international standards for reporting metabolomics experimental results [J].
Castle, Arthur L. ;
Fiehn, Oliver ;
Kaddurah-Daouk, Rima ;
Lindon, John C. .
BRIEFINGS IN BIOINFORMATICS, 2006, 7 (02) :159-165
[7]   Global changes in transcription orchestrate metabolic differentiation during symbiotic nitrogen fixation in Lotus japonicus [J].
Colebatch, G ;
Desbrosses, G ;
Ott, T ;
Krusell, L ;
Montanari, O ;
Kloska, S ;
Kopka, J ;
Udvardi, MK .
PLANT JOURNAL, 2004, 39 (04) :487-512
[8]  
Erban Alexander, 2007, V358, P19, DOI 10.1007/978-1-59745-244-1_2
[9]   Metabolite profiling for plant functional genomics [J].
Fiehn, O ;
Kopka, J ;
Dörmann, P ;
Altmann, T ;
Trethewey, RN ;
Willmitzer, L .
NATURE BIOTECHNOLOGY, 2000, 18 (11) :1157-1161
[10]   The metabolomics standards initiative (MSI) [J].
Fiehn, Oliver ;
Robertson, Don ;
Griffin, Jules ;
van der Werf, Mariet ;
Nikolau, Basil ;
Morrison, Norman ;
Sumner, Lloyd W. ;
Goodacre, Roy ;
Hardy, Nigel W. ;
Taylor, Chris ;
Fostel, Jennifer ;
Kristal, Bruce ;
Kaddurah-Daouk, Rima ;
Mendes, Pedro ;
van Ommen, Ben ;
Lindon, John C. ;
Sansone, Susanna-Assunta .
METABOLOMICS, 2007, 3 (03) :175-178