Ultrahigh-speed optical frequency domain imaging and application to laser ablation monitoring

被引:44
作者
Oh, WY
Yun, SH
Vakoc, BJ
Tearney, GJ
Bouma, BE
机构
[1] Harvard Univ, Sch Med, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Wellman Ctr Photomed, Boston, MA 02114 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1063/1.2179125
中图分类号
O59 [应用物理学];
学科分类号
摘要
We demonstrate a linear laser resonator incorporating a semiconductor optical amplifier and scanning filter for high repetition rate, broad wavelength, unidirectional scanning. The laser operates at up to 115 kHz repetition rates and demonstrates a tuning-speed-independent power of > 30 mW. We apply this laser to enable ultrahigh-speed optical frequency domain imaging of the dynamics of laser ablation of biological tissue. The imaging system acquires single longitudinal scans (A-lines) in 8.7 mu s and complete cross-sectional images comprising 575 A-lines at a rate of 200 frames per second. (c) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 19 条
[1]   High-resolution optical coherence tomography-guided laser ablation of surgical tissue [J].
Boppart, SA ;
Herrmann, J ;
Pitris, C ;
Stamper, DL ;
Brezinski, ME ;
Fujimoto, JG .
JOURNAL OF SURGICAL RESEARCH, 1999, 82 (02) :275-284
[2]   High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Compton, CC ;
Nishioka, NS .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) :467-474
[3]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[4]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[5]   OPTICAL FREQUENCY-DOMAIN REFLECTOMETRY IN SINGLE-MODE FIBER [J].
EICKHOFF, W ;
ULRICH, R .
APPLIED PHYSICS LETTERS, 1981, 39 (09) :693-695
[6]  
*EPASP, EAPPLAB88007609
[7]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[8]  
GOLDBERG BD, 2004, P OSA BIOM OPT TOP M
[9]   Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser [J].
Golubovic, B ;
Bouma, BE ;
Tearney, GJ ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (22) :1704-1706
[10]   Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound [J].
Jang, IK ;
Bouma, BE ;
Kang, DH ;
Park, SJ ;
Park, SW ;
Seung, KB ;
Choi, KB ;
Shishkov, M ;
Schlendorf, K ;
Pomerantsev, E ;
Houser, SL ;
Aretz, HT ;
Tearney, GJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (04) :604-609