Diagnosis of process faults in chemical systems using a local partial least squares approach

被引:88
作者
Kruger, Uwe [1 ]
Dimitriadis, Grigorios [2 ]
机构
[1] Petr Inst, Dept Elect Engn, Abu Dhabi, U Arab Emirates
[2] Univ Liege, Dept Aerosp & Mech Engn, B-4000 Liege 1, Belgium
关键词
condition monitoring; fault detection; fault diagnosis; partial least squares; local approach;
D O I
10.1002/aic.11576
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This article discusses the application of partial least squares (PLS) for monitoring complex chemical systems. In relation to existing work, this article proposes the integration of the statistical local approach into the PLS framework to monitor changes in the underlying model rather than analyzing the recorded input/output data directly. As discussed in the literature, monitoring changes in model parameters addresses the problems of nonstationary behavior and presents an analogy to model-based approaches. The benefits of the proposed technique are that (i) a detailed mechanistic plant model is not required, (ii) nonstationary process behaviour does not produce false alarms, (iii) parameter changes can be non-Gaussian, (iv) Gaussian monitoring statistics can be established to simplify the monitoring task, and (v) fault magnitude and signatures can be estimated. This is demonstrated by a simulation example and the analysis of recorded data from two chemical processes. (C) 2008 American Institute of Chemical Engineers.
引用
收藏
页码:2581 / 2596
页数:16
相关论文
共 43 条
  • [31] A methodology for fault detection, isolation, and identification for nonlinear processes with parametric uncertainties
    Rajaraman, S
    Hahn, J
    Mannan, MS
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (21) : 6774 - 6786
  • [32] RUSSEL EL, 2000, DATA DRIVEN TECHNIQU
  • [33] SHIN R, 1995, IND ENG CHEM RES, V34, P1688
  • [34] SHING CT, 2004, IEEE T ENERGY CONVER, V19, P369
  • [35] AN EVALUATION OF FORECAST-BASED QUALITY-CONTROL SCHEMES
    SUPERVILLE, CR
    ADAMS, BM
    [J]. COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 1994, 23 (03) : 645 - 661
  • [36] MULTIVARIATE CONTROL CHARTS FOR INDIVIDUAL OBSERVATIONS
    TRACY, ND
    YOUNG, JC
    MASON, RL
    [J]. JOURNAL OF QUALITY TECHNOLOGY, 1992, 24 (02) : 88 - 95
  • [37] Fault monitoring of nuclear power plant sensors and field devices
    Upadhyaya, BR
    Zhao, K
    Lu, B
    [J]. PROGRESS IN NUCLEAR ENERGY, 2003, 43 (1-4) : 337 - 342
  • [38] A review of process fault detection and diagnosis Part I: Quantitative model-based methods
    Venkatsubramanian, V
    Rengaswamy, R
    Yin, K
    Kavuri, SN
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2003, 27 (03) : 293 - 311
  • [39] Process monitoring approach using fast moving window PCA
    Wang, X
    Kruger, U
    Irwin, GW
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (15) : 5691 - 5702
  • [40] Recursive partial least squares algorithms for monitoring complex industrial processes
    Wang, X
    Kruger, U
    Lennox, B
    [J]. CONTROL ENGINEERING PRACTICE, 2003, 11 (06) : 613 - 632