Abdominal MR imaging with a volumetric interpolated breath-hold examination

被引:414
作者
Rofsky, NM
Lee, VS
Laub, G
Pollack, MA
Krinsky, GA
Thomasson, D
Ambrosino, MM
Weinreb, JC
机构
[1] NYU Med Ctr, Dept Radiol, New York, NY 10016 USA
[2] Siemens Med Syst Inc, Iselin, NJ 08830 USA
关键词
abdomen; MR; magnetic resonance (MR); technology;
D O I
10.1148/radiology.212.3.r99se34876
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare a T1-weighted, three-dimensional (3D), gradient-echo (GRE) sequence for magnetic resonance (MR) imaging of the body (volumetric interpolated breath-hold examination, or VIBE) with a two-dimensional (2D) GRE breath-hold equivalent. MATERIALS AND METHODS: Twenty consecutive patients underwent 1.5-MR imaging. The examinations included pre- and postcontrast (20 mL gadopentetate dimeglumine) fat-saturated 2D GRE breath-hold imaging and fat-saturated volumetric interpolated breath-hold imaging before, during (arterial phase), and after injection, with thin (2-mm source images) and thick (8-mm reconstruction images) sections. The three images were compared qualitatively and quantitatively (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]). RESULTS: Qualitatively, the 2-mm source images had poorer pancreatic edge definition on precontrast images compared with the other two data sets (P < .05). On gadolinium-enhanced images, scores for clarity of pancreatic edge, number of vessels visualized, and arterial ghosting were significantly lower for the postcontrast 2D GRE images. Quantitatively, SNR measurements in the liver, aorta, and renal cortex on pre- and postcontrast images were significantly higher for the 8-mm reconstruction images than for the 2D GRE or 2-mm source images (P < .05). Aorta-to-fat CNR was significantly higher on the 8-mm reconstruction images. CONCLUSION: Fat-saturated volumetric interpolated breath-hold images have quality comparable to that of conventional fat-saturated 2D GRE images.
引用
收藏
页码:876 / 884
页数:9
相关论文
共 31 条
  • [1] SIGNAL-TO-NOISE RATIO AND SECTION THICKNESS IN TWO-DIMENSIONAL VERSUS 3-DIMENSIONAL FOURIER-TRANSFORM MR IMAGING
    CARLSON, J
    CROOKS, L
    ORTENDAHL, D
    KRAMER, DM
    KAUFMAN, L
    [J]. RADIOLOGY, 1988, 166 (01) : 266 - 270
  • [2] 3-DIMENSIONAL IMAGING AND DISPLAY OF RENAL TUMORS USING SPIRAL CT - A POTENTIAL AID TO PARTIAL NEPHRECTOMY
    CHERNOFF, DM
    SILVERMAN, SG
    KIKINIS, R
    ADAMS, DF
    SELTZER, SE
    RICHIE, JP
    LOUGHLIN, KR
    [J]. UROLOGY, 1994, 43 (01) : 125 - 129
  • [3] REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY
    DU, YPP
    PARKER, DL
    DAVIS, WL
    CAO, G
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 733 - 741
  • [4] Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1996, 201 (03) : 705 - 710
  • [5] Segmental anatomy of the liver: Poor correlation with CT
    Fasel, JHD
    Selle, D
    Evertsz, CJG
    Terrier, F
    Peitgen, HO
    Gailloud, P
    [J]. RADIOLOGY, 1998, 206 (01) : 151 - 156
  • [6] RAPID 3-DIMENSIONAL MR IMAGING USING THE FLASH TECHNIQUE
    FRAHM, J
    HAASE, A
    MATTHAEI, D
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (02) : 363 - 368
  • [7] HEPATIC NEOPLASMS - SURGICALLY RELEVANT SEGMENTAL ANATOMY AND IMAGING TECHNIQUES
    GAZELLE, GS
    HAAGA, JR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (05) : 1015 - 1018
  • [8] Predictive value of magnetic resonance imaging and computerized tomography for conservative renal surgery in an ex vivo tumor enucleation study followed by step-sectioning
    Gschwend, JE
    Vogel, U
    Bader, C
    Mattfeldt, T
    Hautmann, RE
    [J]. JOURNAL OF UROLOGY, 1996, 155 (02) : 451 - 454
  • [9] FOCAL LIVER-LESIONS - CHARACTERIZATION WITH NONENHANCED AND DYNAMIC CONTRAST MATERIAL-ENHANCED MR-IMAGING
    HAMM, B
    THOENI, RF
    GOULD, RG
    BERNARDINO, ME
    LUNING, M
    SAINI, S
    MAHFOUZ, AE
    TAUPITZ, M
    WOLF, KJ
    [J]. RADIOLOGY, 1994, 190 (02) : 417 - 423
  • [10] Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography
    Hany, TF
    Debatin, JF
    Leung, DA
    Pfammatter, T
    [J]. RADIOLOGY, 1997, 204 (02) : 357 - 362