Evaluation of multiwavelength chromatograms for the quantification of mixtures of pesticides by high-performance liquid chromatography diode array detection with multivariate calibration

被引:30
作者
Galera, MM [1 ]
Vidal, JLM [1 ]
Frenich, AG [1 ]
Garcia, MDG [1 ]
机构
[1] UNIV ALMERIA,DEPT ANALYT CHEM,ALMERIA 04071,SPAIN
关键词
chemometrics; multivariate calibration; least-squares analysis; principal component regression; environmental analysis; pesticides;
D O I
10.1016/S0021-9673(97)00371-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three multivariate calibration methods, partial least squares (PLS-1 and PLS-2) and principal component regression, were applied to the simultaneous determination of the five pesticides iprodione, procymidone, chlorothalonil, folpet and triazophos by high-performance liquid chromatography with diode array detection. Such detection gives multiwavelength chromatograms from a single analysis of one sample. In this paper,calibration models at two different wavelengths were developed to resolve mixtures of five pesticides with overlapping chromatographic peaks. The first model, carried out at 220 nm as detector compromise wavelength, yielded satisfactory sensitivity for accurate estimation of the concentration of iprodione, procymidone, chlorothalonil acid folpet and the second model, at 200 nm, was used for accurate estimation of triazophos. Both calibration models were evaluated using the chromatograms and first-derivative (D-1) chromatograms by predicting the concentrations of independent test set samples. Finally, the proposed D-1 calibration models were successfully applied to the determination of these pesticides in groundwater and soil samples. In all cases, the PLS-1 calibration method showed superior quantitative prediction ability than the PLS-2 or principal component regression methods. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:139 / 149
页数:11
相关论文
共 25 条
[1]  
[Anonymous], 1988, Journal of Chemometrics
[2]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[3]   ANALYSIS OF PARTIALLY RESOLVED LIQUID-CHROMATOGRAPHIC PEAKS USING DYNAMIC MODELING WITH THE KALMAN FILTER [J].
BARKER, TQ ;
BROWN, SD .
ANALYTICA CHIMICA ACTA, 1989, 225 (01) :53-68
[4]  
BURDICK DS, 1990, J CHEMOMETR, V4, P15, DOI DOI 10.1002/cem.1180040104
[5]   MULTICOMPONENT CALIBRATION AND ANALYSIS IN LIQUID-CHROMATOGRAPHY [J].
CECIL, TL ;
POE, RB ;
RUTAN, SC .
ANALYTICA CHIMICA ACTA, 1991, 250 (01) :37-44
[6]  
Fell A F, 1983, J Pharm Biomed Anal, V1, P557, DOI 10.1016/0731-7085(83)80069-7
[7]   NOVEL TECHNIQUES FOR PEAK RECOGNITION AND DECONVOLUTION BY COMPUTER-AIDED PHOTODIODE ARRAY DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FELL, AF ;
SCOTT, HP ;
GILL, R ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC) :123-140
[8]  
Frenich AG, 1996, J CHROMATOGR A, V727, P27
[9]  
*G GAL IND, 1992, GRAMS 386 SOFTW PACK
[10]  
Galera MM, 1996, J CHROMATOGR A, V727, P39