MULTICOMPONENT CALIBRATION AND ANALYSIS IN LIQUID-CHROMATOGRAPHY

被引:19
作者
CECIL, TL
POE, RB
RUTAN, SC
机构
关键词
LIQUID CHROMATOGRAPHY; CALIBRATION; FACTOR ANALYSIS; KALMAN FILTER; MULTIWAVELENGTH DETECTION; RANK ANNIHILATION;
D O I
10.1016/0003-2670(91)85060-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multi-wavelength detectors offer improved detection capabilities for liquid chromatographic methods, but require improvements in data analysis methodology to utilize all the available information. In this work, various methods for improving the quantitative results obtained from liquid chromatography with full spectrum fluorescence detection were studied. The availability of multi-wavelength information allows overlapped chromatographic peaks to be resolved. Different approaches were investigated for developing calibration models that use all of the available spectral information, and are compatible with a variety of methods for quantification, including factor analysis, Kalman filtering and rank annihilation. These methods were compared for their ability to resolve overlapped chromatographic peaks and their accuracy in quantification.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 18 条
[1]   RESOLUTION OF A COELUTING CHROMATOGRAPHIC PAIR USING KALMAN FILTERING [J].
BARKER, T ;
BROWN, SD .
JOURNAL OF CHROMATOGRAPHY, 1989, 469 :77-90
[2]   ANALYSIS OF PARTIALLY RESOLVED LIQUID-CHROMATOGRAPHIC PEAKS USING DYNAMIC MODELING WITH THE KALMAN FILTER [J].
BARKER, TQ ;
BROWN, SD .
ANALYTICA CHIMICA ACTA, 1989, 225 (01) :53-68
[3]   THE KALMAN FILTER IN ANALYTICAL-CHEMISTRY [J].
BROWN, SD .
ANALYTICA CHIMICA ACTA, 1986, 181 :1-29
[4]   CORRECTION FOR FLUORESCENCE RESPONSE SHIFTS IN POLYAROMATIC HYDROCARBON MIXTURES WITH AN INNOVATIONS-BASED KALMAN FILTER METHOD [J].
CECIL, TL ;
RUTAN, SC .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :1998-2004
[5]  
CECIL TL, 1990, THESIS
[6]  
CECILL TL, 1991, IN PRESS J CHROMATOG
[7]   COMPUTER-AIDED STRATEGIES FOR ARCHIVE RETRIEVAL AND SENSITIVITY ENHANCEMENT IN THE IDENTIFICATION OF DRUGS BY PHOTODIODE ARRAY DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FELL, AF ;
CLARK, BJ ;
SCOTT, HP .
JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC) :423-440
[8]   QUANTIFICATION OF A KNOWN COMPONENT IN AN UNKNOWN MIXTURE [J].
GAMPP, H ;
MAEDER, M ;
MEYER, CJ ;
ZUBERBUEHLER, AD .
ANALYTICA CHIMICA ACTA, 1987, 193 :287-293
[9]   BACKGROUND SUBTRACTION FOR FLUORESCENCE DETECTION IN THIN-LAYER CHROMATOGRAPHY WITH DERIVATIVE SPECTROMETRY AND THE ADAPTIVE KALMAN FILTER [J].
GEROW, DD ;
RUTAN, SC .
ANALYTICA CHIMICA ACTA, 1986, 184 :53-64
[10]   BACKGROUND CORRECTION FOR FLUORESCENCE DETECTION IN THIN-LAYER CHROMATOGRAPHY USING FACTOR-ANALYSIS AND THE ADAPTIVE KALMAN FILTER [J].
GEROW, DD ;
RUTAN, SC .
ANALYTICAL CHEMISTRY, 1988, 60 (09) :847-852