How muscle architecture and moment arms affect wrist flexion-extension moments

被引:129
作者
Gonzalez, RV
Buchanan, TS
Delp, SL
机构
[1] REHABIL INST CHICAGO, MOTOR PERFORMANCE PROGRAM, CHICAGO, IL 60611 USA
[2] NORTHWESTERN UNIV, DEPT BIOMED ENGN, CHICAGO, IL 60611 USA
[3] NORTHWESTERN UNIV, DEPT PHYS MED & REHABIL, CHICAGO, IL 60611 USA
[4] TOURNEAU UNIV, DEPT MECH ENGN, LONGVIEW, TX 75607 USA
[5] UNIV DELAWARE, DEPT MECH ENGN, NEWARK, DE 19716 USA
关键词
wrist; muscle architecture; moment arms;
D O I
10.1016/S0021-9290(97)00015-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this investigation was to determine how the moment arms and architecture of the wrist muscles influence their isometric moment-generating characteristics. A three-dimensional computer graphics model was developed that estimates the moment arms, maximum isometric forces, and maximum isometric flexion-extension moments generated by 15 muscles about the wrist over a range of wrist flexion angles. In combination with measurements of muscle strength, we used this model to answer three questions: (1) why is peak wrist flexion moment greater than peak extension moment, (2) why does flexion moment vary more with wrist flexion angle than does extension moment, and (3) why does flexion moment peak with the wrist in a flexed position? Analysis of the model revealed that the peak flexion moment is greater than the peak extension moment primarily because of the larger (110%) summed physiologic cross-sectional area of the flexors. The larger variation of flexion moment with flexion angle is caused mainly by; greater variation of the moment arms of the major wrist flexors with flexion angle. The location of the peak flexion moment is determined by the wrist flexion moment arms (which tend to increase with wrist flexion) in combination with the force-length characteristics of these muscles. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:705 / 712
页数:8
相关论文
共 28 条
[1]   DETERMINATION OF MUSCLE ORIENTATIONS AND MOMENT ARMS [J].
AN, KN ;
TAKAHASHI, K ;
HARRIGAN, TP ;
CHAO, EY .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (03) :280-282
[2]  
BERGER RA, 1982, CLIN ORTHOP RELAT R, P303
[3]  
Brand P. W., 1993, CLIN MECH HAND
[4]  
BRAND PW, 1975, J BONE JOINT SURG AM, V57, P779
[5]   ESTIMATION OF MUSCLE FORCES ABOUT THE WRIST JOINT DURING ISOMETRIC TASKS USING AN EMG COEFFICIENT METHOD [J].
BUCHANAN, TS ;
MONIZ, MJ ;
DEWALD, JPA ;
RYMER, WZ .
JOURNAL OF BIOMECHANICS, 1993, 26 (4-5) :547-560
[6]   EVIDENCE THAT MAXIMUM MUSCLE STRESS IS NOT A CONSTANT - DIFFERENCES IN SPECIFIC TENSION IN ELBOW FLEXORS AND EXTENSORS [J].
BUCHANAN, TS .
MEDICAL ENGINEERING & PHYSICS, 1995, 17 (07) :529-536
[7]   A GRAPHICS-BASED SOFTWARE SYSTEM TO DEVELOP AND ANALYZE MODELS OF MUSCULOSKELETAL STRUCTURES [J].
DELP, SL ;
LOAN, JP .
COMPUTERS IN BIOLOGY AND MEDICINE, 1995, 25 (01) :21-34
[8]   AN INTERACTIVE GRAPHICS-BASED MODEL OF THE LOWER-EXTREMITY TO STUDY ORTHOPEDIC SURGICAL-PROCEDURES [J].
DELP, SL ;
LOAN, JP ;
HOY, MG ;
ZAJAC, FE ;
TOPP, EL ;
ROSEN, JM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (08) :757-767
[9]   Maximum isometric moments generated by the wrist muscles in flexion-extension and radial-ulnar deviation [J].
Delp, SL ;
Grierson, AE ;
Buchanan, TS .
JOURNAL OF BIOMECHANICS, 1996, 29 (10) :1371-1375
[10]  
DELP SL, 1992, CLIN ORTHOP RELAT R, P247