Digital edge-detection measurement of polyethylene wear after total hip arthroplasty

被引:91
作者
Shaver, SM
Brown, TD
Hillis, SL
Callaghan, JJ
机构
[1] UNIV IOWA, DEPT ORTHOPAED SURG, IOWA CITY, IA 52242 USA
[2] UNIV IOWA, DEPT BIOMED ENGN, IOWA CITY, IA 52242 USA
[3] UNIV IOWA, DEPT STAT & ACTUARIAL SCI, IOWA CITY, IA 52242 USA
关键词
D O I
10.2106/00004623-199705000-00008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A novel digital edge-detection computer technique was developed to measure polyethylene wear after total hip arthroplasty. The new method objectively infers the margins of the component by evaluating gradients of gray-scale intensity on digitized images of the radiographs. Compared,vith previous methods for measurement of weal; digital edge detection substantially reduces observer subjectivity, The technique was validated directly by measuring wear artificially produced by spherical-front milling of polyethylene liners in a benchtop series, Under such conditions, digital edge detection proved 6.4 times more accurate and 7.1 times more reproducible than manual measurement with conventional circular templates. In addition, clinical application of the new digital imaging technique was illustrated in a series of forty-three patients in whom a metal-backed acetabular cup had been inserted with cement, A random-coefficients prediction algorithm was invoked to estimate longterm wear (mean late rate of wear for the cohort, 0.087 millimeter per year at a mean of 118 months after the operation) on the basis of measurements of short-term wear (mean early rate of wear for the cohort, 0.154 millimeter per year at a mean of twenty-four months). CLINICAL RELEVANCE: Polyethylene wear is a major factor affecting the longevity of a total hip prosthesis. As ten to twenty-year results become available for a variety of bearing surfaces and designs of acetabular components, problems with acetabular wear and loosening have been substantial in too many instances, New techniques for more accurate and reproducible measurement of polyethylene wear should allow earlier detection of deleteriously increased wear and thus permit earlier identification of patients who are at risk and of potentially unacceptable constructs or designs.
引用
收藏
页码:690 / 700
页数:11
相关论文
共 27 条
[1]
LABORATORY WEAR TESTS AND CLINICAL OBSERVATIONS OF THE PENETRATION OF FEMORAL HEADS INTO ACETABULAR CUPS IN TOTAL REPLACEMENT HIP JOINTS .3. THE MEASUREMENT OF INTERNAL VOLUME CHANGES IN EXPLANTED CHARNLEY SOCKETS AFTER 2-16 YEARS INVIVO AND THE DETERMINATION OF WEAR FACTORS [J].
ATKINSON, JR ;
DOWSON, D ;
ISAAC, JH ;
WROBLEWSKI, BM .
WEAR, 1985, 104 (03) :225-244
[2]
Bankston A B, 1993, J Arthroplasty, V8, P315
[3]
CALLAGHAN JJ, 1995, CLIN ORTHOP RELAT R, P14
[4]
CALLAGHAN JJ, 1994, ORTHOP T, V18, P1082
[5]
POLYETHYLENE WEAR IN CEMENTED METAL-BACKED ACETABULAR CUPS [J].
CATES, HE ;
FARIS, PM ;
KEATING, EM ;
RITTER, MA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :249-253
[6]
CHARNLEY J, 1975, CLIN ORTHOP RELAT R, P170
[7]
CLARKE IC, 1976, CLIN ORTHOP RELAT R, P126
[8]
DEVANE PA, 1995, CLIN ORTHOP RELAT R, P303
[9]
DEVANE PA, 1995, CLIN ORTHOP RELAT R, P317
[10]
WEAR AND LOOSENING OF THE HIP-PROSTHESIS - A ROENTGEN STEREOPHOTOGRAMMETRIC 3-YEAR STUDY OF 14 CASES [J].
FRANZEN, H ;
MJOBERG, B .
ACTA ORTHOPAEDICA SCANDINAVICA, 1990, 61 (06) :499-501