A minimally invasive method for the determination of force in the interosseous ligament

被引:13
作者
DeFrate, LE
Li, G [1 ]
Zayontz, SJ
Herndon, JH
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med,Orthopaed Biomech Lab, Beth Israel Deaconess Med Ctr, Boston, MA USA
[2] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
关键词
D O I
10.1016/S0268-0033(01)00092-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Objective. The objective was to develop and utilize a minimally invasive testing system to determine the force in the interosseous ligament under axial compressive loads across the range of motion of the human forearm. Design. Eleven fresh frozen human cadaveric forearms were used (51-72 years). Background. Current studies investigating interosseous ligament forces altered the structure of the forearm by implanting load cells into the radius and ulna. This may affect load transfer through the forearm. Little information was available on interosseous ligament function over the entire flexion range of the elbow. Methods. A robotic joint testing system was used to apply a 100 N compressive load to the forearm and measure the resulting displacement. Each forearm was tested with no disruption of the bones and soft tissues or the forearm. The principle of superposition was used to calculate the forces in the interosseous ligament and was indirectly validated using fluoroscopy. Results. The force in the interosseous ligament ranged from a minimum of 8 N in neutral forearm rotation at full extension to a maximum of 43 N in supination at 30 degrees of flexion. The largest force was found in supination at all flexion angles. Conclusions. The interosseous ligament is an important structure in the stability of the forearm. The force in the interosseous ligament depends on the elbow flexion angle and forearm rotation.
引用
收藏
页码:895 / 900
页数:6
相关论文
共 17 条
[1]
The interosseous membrane affects load distribution in the forearm [J].
Birkbeck, DP ;
Failla, JM ;
Hoshaw, SJ ;
Fyhrie, DP ;
Schaffler, M .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22A (06) :975-980
[2]
DISLOCATION OF THE INFERIOR RADIO-ULNAR JOINT [J].
CURR, JF ;
COE, WA .
BRITISH JOURNAL OF SURGERY, 1946, 34 (133) :74-77
[3]
FRACTURES OF THE RADIAL HEAD WITH DISTAL RADIO-ULNAR DISLOCATION - REPORT OF 2 CASES [J].
ESSEXLOPRESTI, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1951, 33 (02) :244-247
[4]
HERNDON JH, 1999, SURG RECONSTRUCTION
[5]
AN ANATOMIC AND MECHANICAL STUDY OF THE INTEROSSEOUS MEMBRANE OF THE FOREARM - PATHOMECHANICS OF PROXIMAL MIGRATION OF THE RADIUS [J].
HOTCHKISS, RN ;
AN, KN ;
SOWA, DT ;
BASTA, S ;
WEILAND, AJ .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14 (02) :256-261
[6]
HOTCHKISS RN, 1994, HAND CLIN, V10, P391
[7]
The importance of quadriceps and hamstring muscle loading on knee kinematics land in-situ forces in the ACL [J].
Li, G ;
Rudy, TW ;
Sakane, M ;
Kanamori, A ;
Ma, CB ;
Woo, SLY .
JOURNAL OF BIOMECHANICS, 1999, 32 (04) :395-400
[8]
Radioulnar load-sharing in the forearm - A study in cadavera [J].
Markolf, KL ;
Lamey, D ;
Yang, S ;
Meals, R ;
Hotchkiss, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (06) :879-888
[9]
Mechanisms of load transfer in the cadaver forearm: Role of the interosseous membrane [J].
Markolf, KL ;
Dunbar, AM ;
Hannani, K .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (04) :674-682
[10]
FORCE TRANSMISSION THROUGH THE RADIAL HEAD [J].
MORREY, BF ;
AN, KN ;
STORMONT, TJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (02) :250-256