Loading constraints for first swing stability margin enhancement of distributed generation

被引:6
作者
Bidram, A. [1 ,2 ]
Hamedani-Golshan, M-E [1 ]
Davoudi, A. [2 ]
机构
[1] Isfahan Univ Technol, Dept Elect & Comp Engn, Esfahan, Iran
[2] Univ Texas Arlington, Dept Elect Engn, Arlington, TX 76019 USA
关键词
OPTIMAL POWER-FLOW; SENSITIVITY-ANALYSIS; MICROGRIDS; SYSTEMS;
D O I
10.1049/iet-gtd.2012.0018
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study extracts effective loading constraints for synchronous machine-based distributed generators (SMDGs) in a micro-grid to ensure their post-fault first swing stability. The notion of trajectory sensitivity is used to determine the sensitivity of the SMDGs rotor angles and velocities with respect to the mechanical input power. Then, appropriate loading constraints for SMDGs are calculated for a set of pre-specified faults. The proposed methodology can be used for a micro-grid with an arbitrary number of SMDGs, under various fault scenarios, as well as both grid-connected and autonomous (islanded) modes of operation. The proposed methodology is verified using time-domain simulation of a modified benchmark system of the IEEE standard 399-1997.
引用
收藏
页码:1292 / 1300
页数:9
相关论文
共 33 条
[1]  
[Anonymous], 1998, IEEE BROWN BOOK
[2]  
[Anonymous], 2003, IEEE STANDARD 1547
[3]  
Byerly R., 1974, STABILITY LARGE ELEC
[4]   Application of differential evolution algorithm for transient stability constrained optimal power flow [J].
Cai, H. R. ;
Chung, C. Y. ;
Wong, K. P. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (02) :719-728
[5]   Optimal generation rescheduling with sensitivity-based transient stability constraints [J].
Fang, D. Z. ;
Sun, W. ;
Xue, Z. Y. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2010, 4 (09) :1044-1051
[6]   Comparative analysis between synchronous and induction machines for distributed generation applications [J].
Freitas, W ;
Vieira, JCM ;
Morelato, A ;
da Silva, LCP ;
da Costa, VF ;
Lemos, FAB .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (01) :301-311
[7]   Influence of excitation system control modes on the allowable penetration level of distributed synchronous generators [J].
Freitas, W ;
Vieira, JCM ;
Morelato, A ;
Xu, WS .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) :474-480
[8]   Stability-constrained optimal power flow [J].
Gan, DQ ;
Thomas, RJ ;
Zimmerman, RD .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (02) :535-540
[9]  
Haque M. H., 1989, P I ELECT ENG C, P373
[10]   Improvement of first swing stability limit by utilizing full benefit of shunt FACTS devices [J].
Haque, MH .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2004, 19 (04) :1894-1902