A robust multisyringe system for process flow analysis -: Part I.: On-line dilution and single point titration of protolytes

被引:63
作者
Albertús, F
Horstkotte, B
Cladera, A
Cerdá, V [1 ]
机构
[1] Univ Balearic Isl, Dept Chem, Palma de Mallorca 07071, Spain
[2] Univ Appl Sci Hamburg, Sect Environm Engn, D-21033 Hamburg, Germany
关键词
D O I
10.1039/a903496j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A robust multichannel manifold involving a multisyringe piston pump used for performing process flow analysis is proposed. The simultaneous sequential determination of two analytes with a sampling frequency of 97 injections per hour is demonstrated. A robust and rapid continuous flow titration system, including a predilution step, was developed. A quantitative dilution, avoiding the need for diluting the standards too, is achieved in two steps by first splitting the concentrated sample stream and further dilution in a mixing chamber. A wide range of dilution grades (from 80 to 1150) can be easily implemented by software instructions, without the necessity of mechanical reconfiguration of the manifold. The resulting system gives medium or low dispersion peak signals with a sampling frequency of over 75 injections per hour for off-line diluted samples, and more than 33 injections per hour for concentrated samples. The proposed assemblage allows the automation of the single point flow injection titration procedure for the assay of acids and bases in concentrated process solutions. Recoveries of 97.5-103% were found with a maximum RSD value of 5%.
引用
收藏
页码:1373 / 1381
页数:9
相关论文
共 22 条
  • [1] Selective determination of protolytes by flow injection analysis. A guide for the rational selection of reagent composition
    Albertus, F
    Cortes, I
    Danielsson, LG
    Ingman, F
    [J]. ANALYTICA CHIMICA ACTA, 1997, 344 (03) : 271 - 280
  • [2] Albertus F, 1996, PROCESS CONTR QUAL, V8, P185
  • [3] ALBERTUS F, IN PRESS PROCESS CON
  • [4] ALBERTUS F, UNPUB
  • [5] NOVEL SINGLE STANDARD CALIBRATION AND DILUTION METHOD PERFORMED BY THE SEQUENTIAL INJECTION TECHNIQUE
    BARON, A
    GUZMAN, M
    RUZICKA, J
    CHRISTIAN, GD
    [J]. ANALYST, 1992, 117 (12) : 1839 - 1844
  • [6] DETERMINATION OF SULFURIC-ACID IN METALLURGICAL PROCESS STREAMS BY DISCONTINUOUS FLOW-ANALYSIS
    CARDWELL, TJ
    CATTRALL, RW
    CROSS, GJ
    OCONNELL, GR
    PETTY, JD
    SCOLLARY, GR
    [J]. ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) : 197 - 205
  • [7] FLOW-INJECTION TITRATION - LINEAR OR LOGARITHMIC
    CHEN, R
    RUZICKA, J
    CHRISTIAN, GD
    [J]. TALANTA, 1994, 41 (06) : 949 - 955
  • [8] SPLIT ZONE FLOW-INJECTION ANALYSIS - AN APPROACH TO AUTOMATED DILUTIONS
    CLARK, GD
    RUZICKA, J
    CHRISTIAN, GD
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (15) : 1773 - 1778
  • [9] Selective determination of sulfuric acid in liquors from acidic nickel ore extraction by flow injection analysis
    Cortes, I
    Albertus, F
    [J]. ANALYTICA CHIMICA ACTA, 1996, 328 (01) : 61 - 65
  • [10] Cortes I, 1996, QUIM NOVA, V19, P585