Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry

被引:69
作者
Wang, JH [1 ]
Hansen, EH [1 ]
机构
[1] Tech Univ Denmark, Dept Chem, DK-2800 Lyngby, Denmark
关键词
extraction-back extraction; sequential injection; electrothermal atomic absorption spectrometry; assay of certified reference materials; cadmium;
D O I
10.1016/S0003-2670(02)00026-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated sequential injection (SI) on-line solvent extraction-back extraction separation/preconcentration procedure is described. Demonstrated for the assay of cadmium by electrothermal atomic absorption spectrometry (ETAAS), the analyte is initially complexed with ammonium pyrrolidinedithiocarbamate (APDC) in citrate buffer and the chelate is extracted into isobutyl methyl ketone (IBMK), which is separated from the aqueous phase by means of a newly designed dual-conical gravitational phase separator. A metered amount of the organic eluate is aspirated and stored in the PTFE holding coil (HC) of the SI-system. Afterwards, it is dispensed and mixed with an aqueous back extractant of dilute nitric acid containing Hg(II) ions as stripping agent, thereby facilitating a rapid metal-exchange reaction with the APDC ligand and transfer of the Cd into the aqueous phase. The aqueous phase is separated in a second dual-conical gravitational phase separator, and 30 mul of it is entrapped and metered in a sample loop (SL) and subsequently introduced via air segmentation into the graphite tube for analyte quantification. The ETAAS determination is performed in parallel with the separation/preconcentration process of the ensuing sample. An enrichment factor of 21.4, a detection limit of 2.7 ng l(-1), along with a sampling frequency of 13 h(-1) were obtained at a sample flow rate of 6.0 ml min(-1). The precision (R.S.D.) at the 0.4 mug l(-1) level was 1.8% as compared to 3.2% when quantifying the organic extractant directly. The applicability of the procedure is demonstrated for the determination of trace levels of cadmium in three certified reference materials. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:283 / 292
页数:10
相关论文
共 25 条
[1]   DESIGN OF A CONTINUOUS-FLOW 2-STEP EXTRACTION SAMPLE WORK-UP SYSTEM FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BACKSTROM, K ;
DANIELSSON, LG .
ANALYTICA CHIMICA ACTA, 1990, 232 (02) :301-315
[2]   SAMPLE WORK-UP FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY USING CONTINUOUS-FLOW EXTRACTION [J].
BACKSTROM, K ;
DANIELSSON, LG ;
NORD, L .
ANALYST, 1984, 109 :323-325
[3]   STUDIES OF 2-PHASE EQUILIBRIA BY LIQUID LIQUID SEGMENTED FLOW EXTRACTION OF DITHIOCARBAMIC ACIDS INTO VARIOUS SOLVENTS [J].
BACKSTROM, K ;
DANIELSSON, LG ;
INGMAN, F ;
ZHAO, HZ .
TALANTA, 1987, 34 (09) :783-788
[4]  
BACKSTROM K, 1988, ANAL CHEM, V60, P1354
[5]   Improved dithiocarbamate/oxine solvent extraction method for the preconcentration of trace metals from seawater using metal exchange back-extraction [J].
Batterham, GJ ;
Parry, DL .
MARINE CHEMISTRY, 1996, 55 (3-4) :381-388
[6]   PRECONCENTRATION AND MATRIX-ISOLATION OF HEAVY-METALS THROUGH A 2-STAGE SOLVENT-EXTRACTION IN A FLOW SYSTEM [J].
BENGTSSON, M ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1984, 158 (02) :147-156
[7]   Trace metal analysis of natural waters and biological samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow injection on-line adsorption preconcentration using a knotted reactor [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (10) :1349-1356
[8]  
*BOD PARK GMBH, 1995, THGA GRAPH FURN TECH
[9]   EXTRACTION INTO METHYL ISOBUTYL KETONE OF METAL-COMPLEXES WITH AMMONIUM PYRROLIDINE DITHIO-CARBAMATE FORMED IN STRONGLY ACIDIC MEDIA [J].
BROOKS, RR ;
HOASHI, M ;
WILSON, SM ;
ZHANG, RQ .
ANALYTICA CHIMICA ACTA, 1989, 217 (01) :165-170
[10]   Studies on cadmium toxicity in plants: A review [J].
Das, P ;
Samantaray, S ;
Rout, GR .
ENVIRONMENTAL POLLUTION, 1997, 98 (01) :29-36