Determination of rare earth elements in urine by electrothermal vaporization inductively coupled plasma mass spectrometry

被引:25
作者
Bettinelli, M
Spezia, S
Terni, C
Ronchi, A
Balducci, C
Minoia, C
机构
[1] Azienda USL N 1 Pesaro, Novafeltria, Pesaro, Italy
[2] S Maugeri Fdn, Lab Environm Hyg & Ind Toxicol, Pavia, Italy
[3] ENEL, DP, Cent Lab Piacenza, Piancenza, Italy
关键词
D O I
10.1002/rcm.609
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method was developed for the determination of rare earth elements (REEs) in urine with electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICPMS). The undiluted sample was directly injected into the graphite tube and trifluoromethane (Freon-23) was used as chemical modifier in order to reduce the vaporization temperature and the memory effect of most of the lanthanides. The detection limits were in the range 1-10 ng/L with relative standard deviation of 3-5% at concentration levels of 1mug/L, and less than 10-15% at 100 ng/L. Two different procedures, external calibration and a standard additions method, were evaluated to measure the concentration levels of lanthanides in the urine samples and the second procedure was considered to be the best choice for calibration in this work. The level of REEs in urine of 50 healthy volunteers was in the range 5-20 ng/L, above the detection limit of ETV-ICPMS. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:579 / 584
页数:6
相关论文
共 19 条
[1]  
ALLAIN P, 1997, CLIN CHEM, V36, P2012
[2]   Determination of endogenous concentrations of the lanthanides in body fluids and tissues using electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Buseth, E ;
Wibetoe, G ;
Martinsen, I .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :1039-1049
[3]   PLASMA AND TISSUE LEVELS OF SOME LANTHANIDE ELEMENTS IN MALIGNANT AND NON-MALIGNANT HUMAN TISSUES. [J].
Esposito, Mauro ;
Collecchi, Paola ;
Brera, Silvio ;
Mora, Enzo ;
Mazzucotelli, Ambrogio ;
Cutolo, Maurizio ;
Oddone, Massimo .
Science of the Total Environment, 1986, 50 :55-63
[4]   Determination of rare earth elements in blood serum reference sample by chelating resin preconcentration and inductively coupled plasma mass spectrometry [J].
Fujimori, E ;
Tomosue, Y ;
Haraguchi, H .
TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1996, 178 (01) :63-74
[5]   Mechanism of vaporization of yttrium and rare earth elements in electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Goltz, DM ;
Gregoire, DC ;
Chakrabarti, CL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (11) :1365-1382
[6]   ELECTROTHERMAL VAPORIZATION FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY AND ATOMIC-ABSORPTION SPECTROMETRY - SYMBIOTIC ANALYTICAL TECHNIQUES [J].
GREGOIRE, DC ;
LAMOUREUX, M ;
CHAKRABARTI, CL ;
ALMAAWALI, S ;
BYRNE, JP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :579-585
[7]   Fluorination with polytetrafluoroethylene slurry in electrothermal vaporization-inductively coupled plasma-atomic emission spectrometry [J].
Hu, B ;
Jiang, Z ;
Qin, Y ;
Zeng, Y .
ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) :255-264
[8]   A NEW METHOD FOR DETERMINATION OF RARE-EARTH ELEMENTS VAPORIZED IN GRAPHITE-FURNACE WITH A POLYTETRAFLUOROETHYLENE SLURRY FLUORINATING REAGENT BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
HUANG, M ;
JIANG, ZC ;
ZENG, Y .
ANALYTICAL SCIENCES, 1991, 7 (05) :773-778
[9]   FLUORINATION AND VOLATILIZATION OF REFRACTORY ELEMENTS FROM A GRAPHITE-FURNACE FOR SAMPLE INTRODUCTION INTO AN INDUCTIVELY COUPLED PLASMA BY USING A POLYTETRAFLUOROETHYLENE SLURRY [J].
HUANG, M ;
JIANG, ZC ;
ZENG, Y .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (03) :221-224
[10]  
INAGAKI K, 2000, J ANAL ATOM SPECTROM, V125, P191