Regional myocardial perfusion reserve determined using myocardial perfusion magnetic resonance imaging showed a direct correlation with coronary flow velocity reserve by Doppler flow wire

被引:46
作者
Kurita, Tairo [1 ]
Sakuma, Hajime [2 ]
Onishi, Katsuya [3 ]
Ishida, Masaki [2 ]
Kitagawa, Kakuya [2 ]
Yamanaka, Takashi [1 ]
Tanigawa, Takashi [1 ]
Kitamura, Tetsuya [1 ]
Takeda, Kan [2 ]
Ito, Masaaki [1 ]
机构
[1] Mie Univ Hosp, Dept Cardiol, Tsu, Mie 5148507, Japan
[2] Mie Univ Hosp, Dept Diagnost Radiol, Tsu, Mie 5148507, Japan
[3] Mie Univ Hosp, Dept Mol & Lab Med, Tsu, Mie 5148507, Japan
关键词
Cardiac magnetic resonance; Myocardial blood flow; Myocardial perfusion reserve; Doppler flow wire; Coronary flow reserve; EMISSION COMPUTED-TOMOGRAPHY; ARTERY-DISEASE; BLOOD-FLOW; GUIDE-WIRE; ADENOSINE 5'-TRIPHOSPHATE; NONINVASIVE DETECTION; DIAGNOSTIC-ACCURACY; BOLUS INJECTION; GD-DTPA; QUANTIFICATION;
D O I
10.1093/eurheartj/ehn521
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Quantitative analysis of rest-stress myocardial perfusion magnetic resonance imaging (MRI) can provide assessments of regional myocardial perfusion reserve (MPR). The purpose of this study was to compare regional MPR determined by myocardial perfusion MRI with coronary flow reserve (CFR) by intracoronary Doppler flow wire. Twenty patients with suspected coronary artery disease (CAD) were studied. Average peak velocity was measured by Doppler flow wire in the resting state and during adenosine triphosphate (ATP) stress in 36 coronary arteries. CFR measurements for each patient were performed in the culprit and one non-culprit non-stenotic artery. First-pass, contrast-enhanced myocardial perfusion MR images were obtained in the resting state and during ATP stress within the week before the Doppler wire procedure. Regional myocardial blood flow (MBF) was quantified in 16 myocardial segments by analysing arterial input and myocardial output using a Patlak plot method. MPR was calculated as stress MBF divided by rest MBF. CFR measured by Doppler flow wire was compared with MPR in the myocardial segments corresponding to vessel territories. The average MPR measured by perfusion MRI was 1.77 +/- 0.62 for the culprit arteries and 3.45 +/- 0.78 for the non-culprit arteries, respectively (P < 0.001). The averaged CFR by Doppler flow wire was 1.72 +/- 0.44 in the culprit arteries and 3.14 +/- 0.74 in the non-culprit arteries, respectively (P < 0.001). For both culprit and non-culprit vessel groups, significant direct correlations were observed between MR assessments of MPR and Doppler assessments of CFR (culprit artery: R = 0.87, Non-culprit artery: R = 0.86) On Bland-Altman analysis, the mean differences between MPR determined by myocardial perfusion MRI and CFR measured by Doppler wire were 0.05 in culprit arteries (95% limit of agreement; -0.65 to 0.56) and 0.36 in non-culprit arteries (95% limit of agreement; -1.24 to 0.44). The sensitivity and specificity of MR measurement of MPR for predicting physiologically significant reduction of Doppler CFR (< 2) was 88% (95% CI 61.7-98.5) and 90% (95% CI 68.3-98.8), respectively. The current results using Doppler flow wire as a reference method demonstrated that quantitative analysis of stress-rest myocardial perfusion MRI can provide a non-invasive assessment of reduced MPR in patients with CAD.
引用
收藏
页码:444 / 452
页数:9
相关论文
共 44 条
[1]
NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW IN CORONARY-ARTERY DISEASE WITH OXYGEN-15-LABELED CARBON-DIOXIDE INHALATION AND POSITRON EMISSION TOMOGRAPHY [J].
ARAUJO, LI ;
LAMMERTSMA, AA ;
RHODES, CG ;
MCFALLS, EO ;
IIDA, H ;
RECHAVIA, E ;
GALASSI, A ;
DESILVA, R ;
JONES, T ;
MASERI, A .
CIRCULATION, 1991, 83 (03) :875-885
[2]
Contrast-enhanced cardiac MR imaging in the detection of reduced coronary flow velocity reserve [J].
Barmeyer, Achim A. ;
Stork, Alexander ;
Muellerleile, Kai ;
Tiburtius, Claudia ;
Schofer, Anne K. ;
Heitzer, Thomas A. ;
Hofmann, Thomas ;
Adam, Gerhard ;
Meinertz, Thomas ;
Lund, Gunnar K. .
RADIOLOGY, 2007, 243 (02) :377-385
[3]
QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW INVIVO WITH (H2O)-O-15 [J].
BERGMANN, SR ;
FOX, KAA ;
RAND, AL ;
MCELVANY, KD ;
WELCH, MJ ;
MARKHAM, J ;
SOBEL, BE .
CIRCULATION, 1984, 70 (04) :724-733
[4]
Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging [J].
Christian, TF ;
Rettmann, DW ;
Aletras, AH ;
Liao, SL ;
Taylor, JL ;
Balaban, RS ;
Arai, AE .
RADIOLOGY, 2004, 232 (03) :677-684
[5]
Quantitative magnetic resonance perfusion imaging detects anatomic and physiologic coronary artery disease as measured by coronary angiography and fractional flow reserve [J].
Costa, Marco A. ;
Shoemaker, Steven ;
Futamatsu, Hideki ;
Klassen, Chris ;
Anglolillo, Dominick J. ;
Nguyen, Minh ;
Siuciak, Alan ;
Gilmore, Paul ;
Zenni, Martin M. ;
Guzman, Luis ;
Bass, Theodore A. ;
Wilke, Norbert .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (06) :514-522
[6]
Physiologic assessment of coronary artery stenosis by coronary flow reserve measurements with transthoracic Doppler echocardiography: Comparison with exercise thallium-201 single-photon emission computed tomography [J].
Daimon, M ;
Watanabe, H ;
Yamagishi, H ;
Muro, T ;
Akioka, K ;
Hirata, K ;
Takeuchi, K ;
Yoshikawa, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) :1310-1315
[7]
Intracoronary and intravenous adenosine 5′-triphosphate, adenosine, papaverine, and contrast medium to assess fractional flow reserve in humans [J].
De Bruyne, B ;
Pijls, NHJ ;
Barbato, E ;
Bartunek, J ;
Bech, JW ;
Wijns, W ;
Heyndrickx, GR .
CIRCULATION, 2003, 107 (14) :1877-1883
[8]
QUANTIFICATION OF MYOCARDIAL BLOOD-FLOW AND EXTRACELLULAR VOLUMES USING A BOLUS INJECTION OF GD-DTPA - KINETIC MODELING IN CANINE ISCHEMIC DISEASE [J].
DIESBOURG, LD ;
PRATO, FS ;
WISENBERG, G ;
DROST, DJ ;
MARSHALL, TP ;
CARROLL, SE ;
ONEILL, B .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :239-253
[9]
Coronary vasodilator reserve and Framingham risk scores in subjects at risk for coronary artery disease [J].
Dorbala, Sharmila ;
Hassan, Alita ;
Heinonen, Therese ;
Schelbert, Heinrich R. ;
Di Carli, Marcelo F. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (06) :761-767
[10]
VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911