Controlled ion fragmentation in a 2-D quadrupole ion trap for external ion accumulation in ESI FTICR mass spectrometry

被引:23
作者
Belov, ME [1 ]
Gorshkov, MV [1 ]
Udseth, HR [1 ]
Smith, RD [1 ]
机构
[1] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1016/S1044-0305(01)00318-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Undesired fragmentation of electrospray generated ions in an rf multipole traps can be problematic in many applications. Of special interest here is ion dissociation in a 2-D quadrupole ion trap external to a Fourier transform ion cyclotron resonance mass spectrometer (FTICR MS) used in proteomic studies. In this work, we identified the experimental parameters that determine the efficiency of ion fragmentation. We have found that under the pressure conditions used in this study there is a specific combination of the radial and axial potential well depths that determines the fragmentation threshold. This combination of rf and dc fields appears to be universal for ions of different mass-to-charge ratios, molecular weights, and charge states. Such universality allows the fragmentation efficiency of the trapped ions in the course of capillary liquid chromatography (LC) separation studied to be controlled and can increase the useful duty cycle and dynamic range of a FTICR mass spectrometer equipped with an external rf only 2-D quadrupole ion trap. (C) 2001 American Society for Mass Spectrometry.
引用
收藏
页码:1312 / 1319
页数:8
相关论文
共 36 条
  • [1] ANDERSON GA, ICR2LS PNNL
  • [2] Belov ME, 2000, J AM SOC MASS SPECTR, V11, P19, DOI 10.1016/S1044-0305(99)00121-X
  • [3] Zeptomole-sensitivity electrospray ionization - Fourier transform ion cyclotron resonance mass spectrometry of proteins
    Belov, ME
    Gorshkov, MV
    Udseth, HR
    Anderson, GA
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (10) : 2271 - 2279
  • [4] Ion discrimination during ion accumulation in a quadrupole interface external to a Fourier transform ion cyclotron resonance mass spectrometer
    Belov, ME
    Nikolaev, EN
    Harkewicz, R
    Masselon, CD
    Alving, K
    Smith, RD
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) : 205 - 225
  • [5] Electrospray ionization-Fourier transform ion cyclotron mass spectrometry using ion preselection and external accumulation for ultrahigh sensitivity
    Belov, ME
    Nikolaev, EN
    Anderson, GA
    Auberry, KJ
    Harkewicz, R
    Smith, RD
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (01) : 38 - 48
  • [6] Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer
    Belov, ME
    Nikolaev, EN
    Anderson, GA
    Udseth, HR
    Conrads, TP
    Veenstra, TD
    Masselon, CD
    Gorshkov, MV
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (02) : 253 - 261
  • [7] LINKED-SCAN TECHNIQUES FOR MS/MS USING TANDEM-IN-SPACE INSTRUMENTS
    BOYD, RK
    [J]. MASS SPECTROMETRY REVIEWS, 1994, 13 (5-6) : 359 - 410
  • [8] BOUNDARY-EFFECT ACTIVATED DISSOCIATION IN ION-TRAP TANDEM MASS-SPECTROMETRY
    CREASER, CS
    ONEILL, KE
    [J]. ORGANIC MASS SPECTROMETRY, 1993, 28 (05): : 564 - 569
  • [9] DAHLD H, 2000, SIMION 3 D VERSION 7
  • [10] THE EFFECTIVE CONTAINMENT OF PARENT IONS AND DAUGHTER IONS IN TRIPLE QUADRUPOLES USED FOR COLLISIONAL DISSOCIATION
    DAWSON, PH
    FULFORD, JE
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1982, 42 (03): : 195 - 211