Low-dose abdominal CT: Comparison of low tube voltage with moderate-level iterative reconstruction and standard tube voltage, low tube current with high-level iterative reconstruction

被引:24
作者
Kidoh, M. [1 ,2 ]
Nakaura, T. [1 ,2 ]
Nakamura, S. [1 ,2 ]
Oda, S. [2 ]
Utsunomiya, D. [2 ]
Sakai, Y. [3 ]
Harada, K. [4 ]
Yamashita, Y. [2 ]
机构
[1] Amakusa Med Ctr, Amakusa, Kumamoto 8630046, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Honjo, Kumamoto, Japan
[3] Amakusa Med Ctr, Dept Digest Tract Internal Med, Amakusa, Kumamoto 8630046, Japan
[4] Amakusa Med Ctr, Dept Surg, Amakusa, Kumamoto 8630046, Japan
关键词
FILTERED BACK-PROJECTION; IMAGE QUALITY; CONTRAST MATERIAL; DYNAMIC CT; HEPATOCELLULAR-CARCINOMA; RADIATION-EXPOSURE; PULMONARY CT; CANCER-RISKS; THIN ADULTS; ALGORITHM;
D O I
10.1016/j.crad.2013.04.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
AIM: To evaluate the quality of 100 kVp images with a hybrid iterative reconstruction algorithm level of 40% and 120 kVp (low-tube-current) images with a hybrid iterative reconstruction algorithm level of 60% in low-dose abdominal computed tomography (CT) using almost the same radiation dose. MATERIALS AND METHODS: This prospective study received institutional review board approval and written informed consent was obtained. One hundred and ten patients undergoing abdominal dynamic CT were randomly assigned to one of two protocols (100 and 120 kVp protocols). Radiation doses of the two protocols were almost identical. The 120 kVp images were post-processed with a hybrid iterative reconstruction algorithm level of 60% (i-120 kVp). The 100 kVp images were post-processed with a hybrid iterative reconstruction algorithm level of 40% (i-100 kVp). The effective dose (ED), image noise, CT attenuation, and signal-to-noise ratio (SNR) of the subcutaneous fat, muscle, liver, pancreas, and kidneys were compared between the protocols using Student's t-test. Qualitative analysis was also performed between the protocols. RESULTS: There were no significant differences in ED and SNR of any of the regions of interest (ROIs) between the protocols (p > 0.05). However, in the qualitative analysis, unnatural texture was significantly greater in the i-120 kVp than in the i-100 kVp protocol (p < 0.01). There were no other significant differences in the image quality between the protocols (p > 0.05). CONCLUSION: The combined use of low tube voltage and moderate-level iterative reconstruction techniques can be a more effective strategy for reducing patient radiation dose while attaining acceptable image quality than the use of standard tube voltage, low tube current with high-level iterative reconstruction. (C) 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1008 / 1015
页数:8
相关论文
共 29 条
[1]
[Anonymous], BR J RADIOL
[2]
CHARACTERISTICS AND CONTROL OF CONTRAST IN CT [J].
BARNES, JE .
RADIOGRAPHICS, 1992, 12 (04) :825-837
[3]
Image Quality of Low-Energy Pulmonary CT Angiography: Comparison With Standard CT [J].
Bogot, Naama R. ;
Fingerle, Alexander ;
Shaham, Dorith ;
Nissenbaum, Izhak ;
Sosna, Jacob .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) :W273-W278
[4]
Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[6]
Multi-detector row CT angiography of the brain at various kilovoltage settings [J].
Ertl-Wagner, BB ;
Hoffmann, RT ;
Bruning, R ;
Herrmann, K ;
Snyder, B ;
Blume, JD ;
Reiser, MF .
RADIOLOGY, 2004, 231 (02) :528-535
[7]
Combination of a Low-Tube-Voltage Technique With Hybrid Iterative Reconstruction (iDose) Algorithm at Coronary Computed Tomographic Angiography [J].
Funama, Yoshinori ;
Taguchi, Katsuyuki ;
Utsunomiya, Daisuke ;
Oda, Seitaro ;
Yanaga, Yumi ;
Yamashita, Yasuyuki ;
Awai, Kazuo .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (04) :480-485
[8]
Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[9]
Image quality and radiation exposure at pulmonary CT angiography with 100-or 120-kVp protocol: prospective randomized study [J].
Heyer, Christoph M. ;
Mohr, Patrick S. ;
Lemburg, Stefan P. ;
Peters, Soeren A. ;
Nicolas, Volkmar .
RADIOLOGY, 2007, 245 (02) :577-583
[10]
Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435