The effect of opening windows on air change rates in two homes

被引:168
作者
Howard-Reed, C
Wallace, LA
Ott, WR
机构
[1] US EPA, Natl Exposure Res Lab, Reston, VA USA
[2] Stanford Univ, Dept Stat, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Civil & Environm Engn, Stanford, CA 94305 USA
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 2002年 / 52卷 / 02期
关键词
D O I
10.1080/10473289.2002.10470775
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
More than 300 air change rate experiments were completed in two occupied residences: a two-story detached house in Redwood City, CA, and a three-story townhouse in Reston, VA. A continuous monitor was used to measure the decay of SF, tracer gas over periods of 1-18 hr. Each experiment first included a measurement of the air change rate with all exterior doors and windows closed (State 0), then a measurement with the single change from State 0 conditions of opening one or more windows. The overall average State 0 air change rate was 0.37 air changes per hour (hr(-1)) (SD = 0.10 hr(-1); n = 112) for the California house and 0.41 hr(-1) (SD = 0.19 hr(-1); n = 203) for the Virginia house. Indoor/outdoor temperature differences appeared to be responsible for the variation at the Virginia house of 0.15-0.85 hr(-1) when windows were closed. Opening a single window increased the State 0 air change rate by an amount roughly proportional to the width of the opening, reaching increments as high as 0.80 hr(-1) in the California house and 1.3 hr(-1) in the Virginia house. Multiple window openings increased the air change rate by amounts ranging from 0.10 to 2.8 hr(-1) in the California house and from 0.49 to 1.7 hr(-1) in the Virginia house. Compared with temperature differences and wind effects, opening windows produced the greatest increase in the air change rates measured in both homes. Results of this study indicate the importance of occupant window-opening behavior on a home's air change rate and the consequent need to incorporate this factor when estimating human exposure to indoor air pollutants.
引用
收藏
页码:147 / 159
页数:13
相关论文
共 36 条
[1]   Characterization of indoor particle sources: A study conducted in the metropolitan Boston area [J].
Abt, E ;
Suh, HH ;
Allen, G ;
Koutrakis, P .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (01) :35-44
[2]  
[Anonymous], E74100 ASTM
[3]  
[Anonymous], ASHRAE T
[4]  
[Anonymous], 1951, J I HEAT VENT ENG
[5]  
ASHRAE, 1997, ASHRAE Handbook SI (Fundamentals)
[6]  
*ASTM, 1999, E77999 ASTM
[7]  
BREUM NO, 1993, INDOOR AIR S, V1, P3
[8]  
CHASTAIN JP, 1989, ASHRAE T, V95, P256
[9]  
COLOME SD, 1987, P 4 INT C IND AIR, V1, P405
[10]  
COLOME SD, 1994, CALIFORNIA RESIDENTI, V2