Processing gas chromatographic data and confidence interval calculation for partition coefficients determined by the phase ratio variation method

被引:30
作者
Atlan, S
Trelea, IC
Saint-Eve, A
Souchon, I
Latrille, E
机构
[1] INRA, UMR Genie & Microbiol Procedes Alimentaires, INA PG, F-78850 Thiverval Grignon, France
[2] INRA, Lab Biotechnol Environm, F-11100 Narbonne, France
关键词
partition coefficient; Henry's law constant; phase ratio variation (PRV); linear regression; nonlinear regression; parametric method; confidence interval; volatile organic compound;
D O I
10.1016/j.chroma.2006.01.055
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The phase ratio variation (PRV) method is widely used for the determination of partition coefficient values (dimensionless Henry's law constants) by headspace gas chromatography. Traditional data processing by linear regression has several drawbacks: potential bias introduced by linearization, absence of quality indicator of the resulting value and, in case of replicate determinations, poor milisation of the existing measurements leading to unnecessarily large confidence intervals. The paper compares existing PRV data processing methods (linear and nonlinear regression, parametric) and derives confidence intervals for the resulting partition coefficient values. The possibility of using several series of measurements to derive a single partition coefficient value with tighter and more reliable confidence intervals is presented for all three processing methods. The methods are tested on published literature data and new experimental data for 12 volatile organic compounds in water at 25 degrees C. The nonlinear regression based on several series of measurements appears to be the method of choice. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:146 / 155
页数:10
相关论文
共 6 条
[1]  
Bury K., 1999, STAT DISTRIBUTIONS E
[2]   Indirect headspace gas chromatographic method for vapor-liquid phase equilibrium study [J].
Chai, XS ;
Zhu, JY .
JOURNAL OF CHROMATOGRAPHY A, 1998, 799 (1-2) :207-214
[3]   DETERMINATION OF GAS-LIQUID PARTITION-COEFFICIENTS BY AUTOMATIC EQUILIBRIUM HEADSPACE - GAS-CHROMATOGRAPHY UTILIZING THE PHASE RATIO VARIATION METHOD [J].
ETTRE, LS ;
WELTER, C ;
KOLB, B .
CHROMATOGRAPHIA, 1993, 35 (1-2) :73-84
[4]   Partition coefficients of aroma compounds in polysaccharide solutions by the phase ratio variation method [J].
Jouquand, C ;
Ducruet, V ;
Giampaoli, P .
FOOD CHEMISTRY, 2004, 85 (03) :467-474
[5]  
Lincoff A. H., 1984, Gas transfer at water surfaces, P17, DOI [10.1007/978-94-017-1660-4_2, DOI 10.1007/978-94-017-1660-4_2]
[6]   The importance of weighted regression analysis in the determination of Henry's law constants by static headspace gas chromatography [J].
Ramachandran, BR ;
Allen, JM ;
Halpern, AM .
ANALYTICAL CHEMISTRY, 1996, 68 (02) :281-286