liquid xenon;
dark matter;
WIMP;
quenching factor;
pulse shape;
D O I:
10.1016/S0370-2693(01)01411-3
中图分类号:
P1 [天文学];
学科分类号:
0704 ;
摘要:
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40-70 keV. Under the assumption of a single dominant decay component to the scintillation pulse shape the log-normal mean parameter To of the maximum likelihood estimator of the decay time constant for 6 keV < E-ee < 30 keV nuclear recoil events is equal to 21.0 +/- 0.5 ns. It is observed that for electron recoils T-0 rises slowly with energy, having a value similar to 30 ns at E-ee similar to 15 keV. Electron and nuclear recoil pulse shapes are found to be well fitted by single exponential functions although some evidence is found for a double exponential form for the nuclear recoil pulse shape. (C) 2002 Elsevier Science B.V. All rights reserved.