Measurements of scintillation efficiency and pulse shape for low energy recoils in liquid xenon

被引:75
作者
Akimov, D
Bewick, A
Davidge, D
Dawson, J
Howard, AS
Ivaniouchenkov, I
Jones, WG
Joshi, J
Kudryavtsev, VA
Lawson, TB
Lebedenko, V
Lehner, MJ
Lightfoot, PK
Liubarsky, I
Lüscher, R
McMillan, JE
Peak, CD
Quenby, JJ
Spooner, NJC
Sumner, TJ
Tovey, DR
Ward, CK
机构
[1] Univ Sheffield, Dept Phys & Astron, Sheffield S3 7RH, S Yorkshire, England
[2] Inst Theoret & Expt Phys, Moscow 117259, Russia
[3] Univ London Imperial Coll Sci Technol & Med, Blackett Lab, Dept Phys, London SW7 2BZ, England
关键词
liquid xenon; dark matter; WIMP; quenching factor; pulse shape;
D O I
10.1016/S0370-2693(01)01411-3
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40-70 keV. Under the assumption of a single dominant decay component to the scintillation pulse shape the log-normal mean parameter To of the maximum likelihood estimator of the decay time constant for 6 keV < E-ee < 30 keV nuclear recoil events is equal to 21.0 +/- 0.5 ns. It is observed that for electron recoils T-0 rises slowly with energy, having a value similar to 30 ns at E-ee similar to 15 keV. Electron and nuclear recoil pulse shapes are found to be well fitted by single exponential functions although some evidence is found for a double exponential form for the nuclear recoil pulse shape. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 19 条
  • [11] KUDRYATSEV VA, 2000, NUCL INSTRUM METHODS, V456, P272
  • [12] Lindhard J., 1963, Mat. Fys. Medd. Dan. Vid. Selsk, V33, P1, DOI DOI 10.1002/ADMA.200904153
  • [13] Dark matter experiments at the UK Boulby Mine
    Smith, PF
    Smith, NJT
    Lewin, JD
    Homer, GJ
    Alner, GJ
    Arnison, GTJ
    Quenby, JJ
    Sumner, TJ
    Bewick, A
    Ali, T
    Ahmed, B
    Howard, AS
    Davidge, D
    Joshi, M
    Jones, WG
    Davies, G
    Liubarsky, I
    Smith, RAD
    Spooner, NJC
    Roberts, JW
    Tovey, DR
    Lehner, MJ
    McMillan, JE
    Peak, CD
    Kudryatsev, VA
    Barton, JC
    [J]. PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS, 1998, 307 (1-4): : 275 - 282
  • [14] Improved dark matter limits from pulse shape discrimination in a low background sodium iodide detector at the Boulby mine
    Smith, PF
    Arnison, GTJ
    Homer, GJ
    Lewin, JD
    Alner, GJ
    Spooner, NJC
    Quenby, JJ
    Sumner, TJ
    Bewick, A
    Li, JP
    Shaul, D
    Ali, T
    Jones, WG
    Smith, NJT
    Davies, GJ
    Lally, CH
    vandenPutte, MJ
    Barton, JC
    Blake, PR
    [J]. PHYSICS LETTERS B, 1996, 379 (1-4) : 299 - 308
  • [15] THE SCINTILLATION EFFICIENCY OF SODIUM AND IODINE RECOILS IN A NAI(TL) DETECTOR FOR DARK-MATTER SEARCHES
    SPOONER, NJC
    DAVIES, GJ
    DAVIES, JD
    PYLE, GJ
    BUCKNELL, TD
    SQUIER, GTA
    LEWIN, JD
    SMITH, PF
    [J]. PHYSICS LETTERS B, 1994, 321 (1-2) : 156 - 160
  • [16] Measurement of Na and I recoil discrimination and detection efficiency in a cooled 'UVIS' NaI crystal for dark matter searches
    Spooner, NJC
    Davies, GJ
    Lally, CH
    Smith, NJT
    vandenPutte, M
    Smith, PF
    Lewin, JD
    Squier, GTA
    Jagpal, P
    [J]. ASTROPARTICLE PHYSICS, 1996, 5 (3-4) : 299 - 307
  • [17] SUMNER TJ, 1999, P 26 ICRC, V2, P516
  • [18] Measurement of scintillation efficiencies and pulse-shapes for nuclear recoils in NaI(Tl) and CaF2(Eu) at low energies for dark matter experiments
    Tovey, DR
    Kudryavtsev, V
    Lehner, M
    McMillan, JE
    Peak, CD
    Roberts, JW
    Spooner, NJC
    Lewin, JD
    [J]. PHYSICS LETTERS B, 1998, 433 (1-2) : 150 - 155
  • [19] TOVEY DR, 1998, THESIS U SHEFFIELD