The position of the centre of the femoral head relative to the midline of the pelvis: A consistent landmark in total knee replacement surgery

被引:7
作者
Alazzawi, Sulaiman [1 ]
Field, Michael H. [2 ]
Bardakos, Nikolaos V. [3 ]
Freeman, Michael A. R. [4 ,5 ]
Field, Richard E. [3 ]
机构
[1] Univ Coll London Hosp, London NW1 2BU, England
[2] Univ London Imperial Coll Sci Technol & Med, London, England
[3] S W London Elect Orthopaed Ctr, Epsom, Surrey, England
[4] Royal London Hosp, London E1 1BB, England
[5] Charles Univ Prague, Prague, Czech Republic
关键词
Centre of the femoral head; Total knee replacement; ARTHROPLASTY; HIP; ALIGNMENT; ROTATION; CHILDREN; GUIDES; FEMUR; TKA;
D O I
10.1016/j.knee.2012.04.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Femoro-tibial malalignment in excess of 3 degrees is a recognised contributor of early mechanical failure in total knee replacement (TKR). Knowledge of the location of the centre of the femoral head is a pre-requisite to identification of the mechanical axis of the femur and can facilitate optimal component orientation. We investigated variation in the location of the centre of the femoral head relative to the midline of the pelvis. Methods: We analysed the pelvic radiographs of 150 patients with unilateral total hip replacements. The perpendicular distance from the centre of the femoral head of the non-operated hip to the centre of pubic symphysis was measured. Results: The mean distance from the centre of the femoral head to the pubic symphysis was 89.2 mm (standard deviation, 5.7 mm). Patient height strongly correlated with this distance (r = 0.53, p<0.01), as did the diameter of the femoral head (r = 0.59, p<0.01). The latter was significantly larger in men than in women (50.9 mm vs. 44.5 mm, p<0.01). Conclusion: The results demonstrate that the position of the centre of the femoral head has very little variability, irrespective of patient age or body-mass index. If the gender-specific mean femoral head to midline distance is used to estimate the location of the femoral head centre, a line from this point to the centre of the femoral condyles will deviate from the true mechanical axis by no more than 1.5 degrees, in 98% of cases. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:827 / 831
页数:5
相关论文
共 23 条
[1]
DISTRIBUTION OF LENGTHS OF THE NORMAL FEMUR AND TIBIA IN CHILDREN FROM ONE TO 18 YEARS OF AGE [J].
ANDERSON, M ;
MESSNER, MB ;
GREEN, WT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1964, 46 (06) :1197-1202
[2]
Radiographic assessment of alignment following TKA: outline of a standardized protocol and assessment of a newly devised trigonometric method of analysis [J].
Balakrishnan, Vikram ;
De Steiger, Richard ;
Lowe, Adrian .
ANZ JOURNAL OF SURGERY, 2010, 80 (05) :344-349
[3]
Mechanical axis cannot be restored in total knee arthroplasty with a fixed valgus resection angle - A radiographic study [J].
Bardakos, Nicholas ;
Cil, Akin ;
Thompson, Brandon ;
Stocks, Greg .
JOURNAL OF ARTHROPLASTY, 2007, 22 (06) :85-89
[4]
BARGREN JH, 1983, CLIN ORTHOP RELAT R, P178
[5]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]
Clark J M, 1987, J Arthroplasty, V2, P99, DOI 10.1016/S0883-5403(87)80016-5
[7]
A Systematic Approach to the Plain Radiographic Evaluation of the Young Adult Hip [J].
Clohisy, John C. ;
Carlisle, John C. ;
Beaule, Paul E. ;
Kim, Young-Jo ;
Trousdale, Robert T. ;
Sierra, Rafael J. ;
Leunig, Michael ;
Schoenecker, Perry L. ;
Millis, Michael B. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A :47-66
[8]
Freeman MAR, 1991, F S MODULAR TOTAL KN
[9]
Freeman MAR, 2006, CZECH SOC ORTHOPAEDI
[10]
JIANG CC, 1989, CLIN ORTHOP RELAT R, P50