Radiographic assessment of alignment following TKA: outline of a standardized protocol and assessment of a newly devised trigonometric method of analysis

被引:3
作者
Balakrishnan, Vikram [1 ]
De Steiger, Richard [2 ]
Lowe, Adrian [3 ]
机构
[1] St Vincents Hosp, Melbourne, Vic 3073, Australia
[2] Epworth Med Fdn, Dept Orthopaed Surg, Melbourne, Vic, Australia
[3] Royal Melbourne Hosp, Clin Epidemiol & Hlth Serv Unit, Melbourne, Vic, Australia
关键词
radiographs; total knee arthroplasty; trigonometric method; TOTAL KNEE ARTHROPLASTY; REPLACEMENT; PROSTHESIS; NAVIGATION;
D O I
10.1111/j.1445-2197.2009.05198.x
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
Background: An important determinant of long-term outcomes following total knee arthrolplasty (TKA) is post-operative alignment as measured on radiographs. Thus far, radiographs have been measured using the goniometer method (GM) and no standard protocol has been followed. The aim of this prospective study was to: (i) outline a protocol for radiographic measurement following TKA; and (ii) compare the accuracy of the traditional GM with a new trigonometric method (TM) of radiographic analysis. Methods: A protocol for the measurement of alignment on radiographs following TKA was outlined in detail with step-by-step instructions. A new TM of angle measurement was also delineated. Alignment was measured on 51 post-operative TKA radiographs. A single angle was chosen and measured by two observers using both the GM and TM. Results: The TM had a precision of 1.06 degrees compared with 1.5 degrees using the GM. The standard deviation of the TM was significantly smaller than the GM (P = 0.033). The intra-class correlation coefficient of the TM was 0.94 versus 0.90 for the GM. Conclusion: The study detailed a protocol for the measurement of axial alignment of the limbs and components following TKA, and provided evidence that a newer TM of angle measurement was superior in terms of precision and intra-rater reliability in comparison with the traditional method.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 18 条
[1]
BARGREN JH, 1983, CLIN ORTHOP RELAT R, P178
[2]
Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[3]
Tibial component failure mechanisms in total knee arthroplasty [J].
Berend, ME ;
Ritter, MA ;
Meding, JB ;
Faris, PM ;
Keating, EM ;
Redelman, R ;
Faris, GW ;
Davis, KE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :26-34
[4]
CATES HE, 1993, CLIN ORTHOP RELAT R, P32
[5]
Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[6]
Goniometric versus computerized angle measurement in assessing hallux valgus [J].
Farber, DC ;
DeOrio, JK ;
Steel, MW .
FOOT & ANKLE INTERNATIONAL, 2005, 26 (03) :234-238
[7]
Is there an alternative to the full-leg radiograph for determining knee joint alignment in osteoarthritis? [J].
Hinman, RS ;
May, RL ;
Crossley, KM .
ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2006, 55 (02) :306-313
[8]
TOTAL CONDYLAR KNEE ARTHROPLASTY - PROSTHETIC COMPONENT POSITIONING AND RADIOLUCENT LINES [J].
HVID, I ;
NIELSEN, S .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (02) :160-165
[9]
CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[10]
Laskin RS, 2001, CLIN ORTHOP RELAT R, P95