Intracardiac phased-array imaging: Methods and initial clinical experience with high resolution, under blood visualization - Initial experience with intracardiac phased-array ultrasound

被引:78
作者
Packer, DL [1 ]
Stevens, CL [1 ]
Curley, MG [1 ]
Bruce, CJ [1 ]
Miller, FA [1 ]
Khandheria, BK [1 ]
Oh, JK [1 ]
Sinak, LJ [1 ]
Seward, JB [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Div Cardiol, Rochester, MN 55905 USA
关键词
D O I
10.1016/S0735-1097(01)01764-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study was designed to test the feasibility of high-resolution phased-array intracardiac imaging. BACKGROUND Intracardiac echocardiographic imaging of the heart during interventional electrophysiologic (EP) procedures has been limited by inadequate ultrasound penetration and absence of Doppler hemodynamic and flow information produced by rotating mechanical ultrasound elements. METHODS A 10F (3.2 mm) phased-array, variable 5.5 to 10 MHz frequency imaging catheter with a four-way deflectable tip was applied in 24 patients undergoing EP studies. Sixteen prespecified cardiac targets were imaged from a right heart venue. RESULTS Fifteen patients had no underlying organic heart disease; nine had ischemic, cardiomyopathic, valvular or congenital heart disorders. Longitudinal and short-axis imaging readily disclosed each cardiac valve, support structures and chamber, as well as the pericardium, right and left atrial appendages, the junction of the right atrium and superior vena cava, crista terminalis, tricuspid valve isthmus, coronary sinus orifice, membranous fossa ovalis and pulmonary veins. The average target depth was 8.8 +/- 1.5 cm (range 0.5 to 15 cm), with adequate penetration at a 7.5 MHz imaging frequency. Color flow and Doppler utilities clearly characterized transaortic and pulmonic valve and pulmonary vein blood flow, including during low output states. CONCLUSIONS These first human studies with this technology demonstrate the methods, feasibility and utility of intracardiac phased-array vector and Doppler imaging for long-axis, apex-to-base global cardiac imaging. High resolution of endocardial structures and catheters suggests additional utility for visualizing interventional procedures from the right heart. (C) 2002 by the American College of Cardiology.
引用
收藏
页码:509 / 516
页数:8
相关论文
共 28 条
  • [1] Chavan A, 1997, CIRCULATION, V96, P2124
  • [2] INTRACARDIAC ECHOCARDIOGRAPHY DURING RADIOFREQUENCY CATHETER ABLATION OF CARDIAC-ARRHYTHMIAS IN HUMANS
    CHU, E
    KALMAN, JM
    KWASMAN, MA
    JUE, JCY
    FITZGERALD, PJ
    EPSTEIN, LM
    SCHILLER, NB
    YOCK, PG
    LESH, MD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (05) : 1351 - 1357
  • [3] Catheter tip orientation affects radiofrequency ablation lesion size in the canine left ventricle
    Chugh, SS
    Chan, RC
    Johnson, SB
    Packer, DL
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (03): : 413 - 420
  • [4] GUIDANCE OF RADIOFREQUENCY CATHETER ABLATION BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN CHILDREN WITH PALLIATED SINGLE VENTRICLE
    DRANT, SE
    KLITZNER, TS
    SHANNON, KM
    WETZEL, GT
    WILLIAMS, RG
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (17) : 1311 - &
  • [5] Nonfluoroscopic transseptal catheterization: Safety and efficacy of intracardiac echocardiographic guidance
    Epstein, LM
    Smith, T
    TenHoff, H
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (06) : 625 - 630
  • [6] Multiplane transesophageal imaging during transcatheter closure of an atrial septal defect
    Fehske, W
    Pfeiffer, D
    Babic, U
    Luderitz, B
    [J]. CIRCULATION, 1997, 96 (05) : 1702 - 1703
  • [7] Adjunctive intracardiac echocardiography to guide slow pathway ablation in human atrioventricular nodal reentrant tachycardia - Anatomic insights
    Fisher, WG
    Pelini, MA
    Bacon, ME
    [J]. CIRCULATION, 1997, 96 (09) : 3021 - 3029
  • [8] TRANSESOPHAGEAL ULTRASOUND IMAGING DURING STENT IMPLANTATION TO RELIEVE SUPERIOR VENA CAVA-TO-INTRA-ATRIAL BAFFLE OBSTRUCTION AFTER MUSTARD REPAIR OF TRANSPOSITION OF THE GREAT-ARTERIES
    GE, SP
    SHIOTA, T
    RICE, MJ
    HELLENBRAND, WM
    SAHN, DJ
    [J]. CIRCULATION, 1995, 91 (10) : 2679 - 2680
  • [9] TRANSESOPHAGEAL ECHOCARDIOGRAPHY TO IMPROVE POSITIONING OF RADIOFREQUENCY ABLATION CATHETERS IN LEFT-SIDED WOLFF-PARKINSON-WHITE SYNDROME
    GOLDMAN, AP
    IRWIN, JM
    GLOVER, MU
    MICK, W
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (08): : 1245 - 1250
  • [10] KALMAN JLR, 1995, CIRCULATION, P3070