Revised exponential model for mass bias correction using an internal standard for isotope abundance ratio measurements by multi-collector inductively coupled plasma mass spectrometry

被引:128
作者
Baxter, DC
Rodushkin, I
Engström, E
Malinovsky, D
机构
[1] Analyt AB, SE-97775 Lulea, Sweden
[2] Lulea Univ Technol, Div Appl Geol, SE-97187 Lulea, Sweden
关键词
D O I
10.1039/b517457k
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
An internal standard (IS) can be used to account for moderate, matrix-related shifts in mass bias using multi-collector inductively coupled plasma mass spectrometry through the empirical, linear relationship between measured isotope abundance ratios for different elements in ln-ln space. Unfortunately, erroneous mass bias corrected isotope abundance ratios may be returned by the model, requiring artificial adjustment of the true isotope abundance ratio of the IS. Although inadequate correction for peak tailing has been convincingly used to explain this problem, our analysis of the literature describing the development of the mass bias correction model using an IS reveals the presence of a source of systematic error. The origin of this error is purely mathematical and is eliminated in the revised model presented, in which mass bias corrected isotope abundance ratios are independent of the isotopic composition of the IS. An expression for computing the total combined uncertainty in the corrected ratio, incorporating contributions from the linear model, the isotopic reference material, and measurements of analyte element and IS in the sample, is also derived.
引用
收藏
页码:427 / 430
页数:4
相关论文
共 20 条
[1]
Precise and accurate isotopic measurements using multiple-collector ICPMS [J].
Albarède, F ;
Telouk, P ;
Blichert-Toft, J ;
Boyet, M ;
Agranier, A ;
Nelson, B .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (12) :2725-2744
[2]
Precise determination of mass-dependent variations in the isotopic composition of molybdenum using MC-ICPMS [J].
Anbar, AD ;
Knab, KA ;
Barling, J .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1425-1431
[3]
Mass discrimination correction in multiple-collector plasma source mass spectrometry: an example using Cu and Zn isotopes [J].
Archer, C ;
Vance, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (05) :656-665
[4]
Fe isotope variations in natural materials measured using high mass resolution multiple collector ICPMS [J].
Arnold, GL ;
Weyer, S ;
Anbar, AD .
ANALYTICAL CHEMISTRY, 2004, 76 (02) :322-327
[5]
A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes [J].
Belshaw, NS ;
Freedman, PA ;
O'Nions, RK ;
Frank, M ;
Guo, Y .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :51-58
[6]
Atomic weights of the elements:: Review 2000 -: (IUPAC technical report) [J].
De Laeter, JR ;
Böhlke, JK ;
De Bièvre, P ;
Hidaka, H ;
Peiser, HS ;
Rosman, KJR ;
Taylor, PDP .
PURE AND APPLIED CHEMISTRY, 2003, 75 (06) :683-800
[7]
EURACHEM/CITAC, 2000, QUANT UNC AN MEAS
[8]
DETERMINATION OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) [J].
LONGERICH, HP ;
FRYER, BJ ;
STRONG, DF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) :39-48
[9]
MACTAGGART DL, 1992, J AOAC INT, V75, P594
[10]
Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry [J].
Maréchal, CN ;
Télouk, P ;
Albarède, F .
CHEMICAL GEOLOGY, 1999, 156 (1-4) :251-273