Preanalytical Aspects and Sample Quality Assessment in Metabolomics Studies of Human Blood

被引:234
作者
Yin, Peiyuan [1 ]
Peter, Andreas [2 ,3 ]
Franken, Holger [4 ]
Zhao, Xinjie [1 ]
Neukamm, Sabine S. [2 ,3 ]
Rosenbaum, Lars [4 ]
Lucio, Marianna [5 ]
Zell, Andreas [4 ]
Haering, Hans-Ulrich [3 ,6 ]
Xu, Guowang [1 ]
Lehmann, Rainer [2 ,3 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, CAS Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
[2] Univ Hosp Tuebingen, Div Clin Chem & Pathobiochem, Cent Lab, D-72076 Tubingen, Germany
[3] Univ Tubingen, Helmholtz Ctr Munich, Inst Diabet Res & Metab Dis, Paul Langerhans Inst Tubingen, Tubingen, Germany
[4] Univ Tubingen, Ctr Bioinformat ZBIT, Tubingen, Germany
[5] Inst Ecol Chem, German Res Ctr Environm Hlth, Helmholtz Ctr Munich, Neuherberg, Germany
[6] Univ Tubingen, Div Endocrinol Diabetol Vasc Med Nephrol & Clin C, Dept Internal Med, Tubingen, Germany
关键词
LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY; MASS-SPECTROMETRY; SPHINGOSINE; 1-PHOSPHATE; BIOMARKER DISCOVERY; GAS-CHROMATOGRAPHY; HUMAN PLASMA; UPLC-MS; SERUM; COLLECTION; EXTRACTION;
D O I
10.1373/clinchem.2012.199257
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Metabolomics is a powerful tool that is increasingly used in clinical research. Although excellent sample quality is essential, it can easily be compromised by undetected preanalytical errors. We set out to identify critical preanalytical steps and biomarkers that reflect preanalytical inaccuracies. METHODS: We systematically investigated the effects of preanalytical variables (blood collection tubes, hemolysis, temperature and time before further processing, and number of freeze-thaw cycles) on metabolomics studies of clinical blood and plasma samples using a nontargeted LC-MS approach. RESULTS: Serum and heparinate blood collection tubes led to chemical noise in the mass spectra. Distinct, significant changes of 64 features in the EDTA-plasma metabolome were detected when blood was exposed to room temperature for 2, 4, 8, and 24 h. The resulting pattern was characterized by increases in hypoxanthine and sphingosine 1-phosphate (800% and 380%, respectively, at 2 h). In contrast, the plasma metabolome was stable for up to 4 h when EDTA blood samples were immediately placed in iced water. Hemolysis also caused numerous changes in the metabolic profile. Unexpectedly, up to 4 freeze-thaw cycles only slightly changed the EDTA-plasma metabolome, but increased the individual variability. CONCLUSIONS: Nontargeted metabolomics investigations led to the following recommendations for the preanalytical phase: test the blood collection tubes, avoid hemolysis, place whole blood immediately in ice water, use EDTA plasma, and preferably use nonrefrozen biobank samples. To exclude outliers due to preanalytical errors, inspect the biomarker signal intensities reflecting systematic as well as accidental and preanalytical inaccuracies before processing the bioinformatics data. (C) 2013 American Association for Clinical Chemistry
引用
收藏
页码:833 / 845
页数:13
相关论文
共 38 条
[1]  
[Anonymous], 2007, ANAL BIOCH
[2]   Influences of biofluid sample collection and handling procedures on GC-MS based metabolomic studies [J].
Bando, Kiyoko ;
Kawahara, Rui ;
Kunimatsu, Takeshi ;
Sakai, Jun ;
Kimura, Juki ;
Funabashi, Hitoshi ;
Seki, Takaki ;
Bamba, Takeshi ;
Fukusaki, Eiichiro .
JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2010, 110 (04) :491-499
[3]   Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks [J].
Bernini, Patrizia ;
Bertini, Ivano ;
Luchinat, Claudio ;
Nincheri, Paola ;
Staderini, Samuele ;
Turano, Paola .
JOURNAL OF BIOMOLECULAR NMR, 2011, 49 (3-4) :231-243
[4]   Large-scale human metabolomics studies: A strategy for data (pre-) processing and validation [J].
Bijlsma, S ;
Bobeldijk, L ;
Verheij, ER ;
Ramaker, R ;
Kochhar, S ;
Macdonald, IA ;
van Ommen, B ;
Smilde, AK .
ANALYTICAL CHEMISTRY, 2006, 78 (02) :567-574
[5]  
Boyanton BL, 2002, CLIN CHEM, V48, P2242
[6]   Preanalytical standardization of amino acid and acylcarnitine metabolite profiling in human blood using tandem mass spectrometry [J].
Brauer, Romy ;
Leichtle, Alexander Benedikt ;
Fiedler, Georg Martin ;
Thiery, Joachim ;
Ceglarek, Uta .
METABOLOMICS, 2011, 7 (03) :344-352
[7]   Evaluation of a protocol for metabolic profiling studies on human blood plasma by combined ultra-performance liquid chromatography/mass spectrometry: From extraction to data analysis [J].
Bruce, Stephen J. ;
Jonsson, Par ;
Antti, Henrik ;
Cloarec, Olivier ;
Trygg, Johan ;
Marklund, Stefan L. ;
Moritz, Thomas .
ANALYTICAL BIOCHEMISTRY, 2008, 372 (02) :237-249
[8]   Investigation of Human Blood Plasma Sample Preparation for Performing Metabolomics Using Ultrahigh Performance Liquid Chromatography/Mass Spectrometry [J].
Bruce, Stephen J. ;
Tavazzi, Isabelle ;
Parisod, Veronique ;
Rezzi, Serge ;
Kochhar, Sunil ;
Guy, Philippe A. .
ANALYTICAL CHEMISTRY, 2009, 81 (09) :3285-3296
[9]   Exploring the Initial Steps of the Testing Process: Frequency and Nature of Pre-Preanalytic Errors [J].
Carraro, Paolo ;
Zago, Tatiana ;
Plebani, Mario .
CLINICAL CHEMISTRY, 2012, 58 (03) :638-642
[10]   Practical approach for the identification and isomer elucidation of biomarkers detected in a metabonomic study for the discovery of individuals at risk for diabetes by integrating the chromatographic and mass spectrometric information [J].
Chen, Jing ;
Zhao, Xinjie ;
Fritsche, Jens ;
Yin, Peiyuan ;
Schmitt-Kopplin, Philippe ;
Wang, Wenzhao ;
Lu, Xin ;
Haring, Hans Ulrich ;
Schleicher, Erwin D. ;
Lehmann, Rainer ;
Xu, Guowang .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :1280-1289