Diagnosis and staging of ovarian cancer: Comparative values of Doppler and conventional US, CT, and MR imaging correlated with surgery and histopathologic analysis - Report of the Radiology Diagnostic Oncology Group

被引:162
作者
Kurtz, AB
Tsimikas, JV
Tempany, CMC
Hamper, UM
Arger, PH
Bree, RL
Wechsler, RJ
Francis, IR
Kuhlman, JE
Siegelman, ES
Mitchell, DG
Silverman, SG
Brown, DL
Sheth, S
Coleman, BG
Ellis, JH
Kurman, RJ
Caudry, DJ
McNeil, BJ
机构
[1] Thomas Jefferson Univ, Jefferson Med Coll, Dept Radiol, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ Hosp, Philadelphia, PA 19107 USA
[3] Harvard Univ, Sch Med, Dept Hlth Care Policy, Boston, MA 02115 USA
[4] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[5] Johns Hopkins Hosp, Dept Radiol, Baltimore, MD 21287 USA
[6] Johns Hopkins Hosp, Dept Pathol, Baltimore, MD 21287 USA
[7] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[8] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
computed tomography (CT); comparative studies; magnetic resonance (MR); ovary; neoplasms; receiver operating characteristic curve (ROC); ultrasound; (US); Doppler studies;
D O I
10.1148/radiology.212.1.r99jl3619
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the optimal imaging modality for diagnosis and staging of ovarian cancer. MATERIALS AND METHODS: Two hundred eighty women suspected to have ovarian cancer were enrolled in a prospective study before surgery. Doppler ultrasonography (US), computed tomography (CT), and magnetic resonance (MR) imaging were used to evaluate the mass; conventional US, CT, and MR imaging were used to stage spread. RESULTS: All three modalities had high accuracy (0.91) for the overall diagnosis of malignancy. In the ovaries, the accuracy of MR imaging (0.91) was higher than that of CT and significantly higher than that of Doppler US (0.78). In the extraovarian pelvis and in the abdomen, conventional US, CT, and MR imaging had similar accuracies (0.87-0.95). In differentiation of disease confined to the pelvis from abdominal spread, the specificity of conventional Us (96%) was higher than that of CT and significantly higher than that of MR imaging (88%), whereas the sensitivities of MR imaging (98%) and CT (92%) were significantly higher than that of conventional US (75%). CONCLUSION: MR imaging is superior to Doppler US and CT in diagnosis of malignant ovarian masses. There is little variation among conventional US, CT, and MR imaging as regards staging.
引用
收藏
页码:19 / 27
页数:9
相关论文
共 49 条
[31]  
NGUYEN HN, 1993, CANCER, V72, P3663, DOI 10.1002/1097-0142(19931215)72:12<3663::AID-CNCR2820721218>3.0.CO
[32]  
2-S
[33]   Benign and malignant gynecologic disease: Clinical importance of fluid and peritoneal enhancement in the pelvis at MR imaging [J].
Outwater, EK ;
Siegelman, ES ;
Wilson, KM ;
Mitchell, DG .
RADIOLOGY, 1996, 200 (02) :483-488
[34]  
Puls LE, 1997, SOUTHERN MED J, V90, P1097
[35]   Transvaginal ultrasonography of pelvic masses: Evaluation of B-mode technique and Doppler ultrasonography [J].
Rehn, M ;
Lohmann, K ;
Rempen, A .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1996, 175 (01) :97-104
[36]  
ROBBOY SJ, 1987, BLAUSTEINS PATHOLOGY, P925
[37]  
RULIN MC, 1987, OBSTET GYNECOL, V70, P578
[38]  
SASSONE AM, 1991, OBSTET GYNECOL, V78, P70
[39]   PRIMARY OVARIAN-CANCER - PROSPECTIVE COMPARISON OF CONTRAST-ENHANCED CT AND PRECONTRAST AND POSTCONTRAST, FAT-SUPPRESSED MR IMAGING, WITH HISTOLOGIC CORRELATION [J].
SEMELKA, RC ;
LAWRENCE, PH ;
SHOENUT, JP ;
HEYWOOD, M ;
KROEKER, MA ;
LOTOCKI, R .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01) :99-106
[40]   A COMPARATIVE-STUDY OF THE ACCURACY OF ULTRASOUND IMAGING, X-RAY COMPUTERIZED-TOMOGRAPHY AND LOW FIELD MRI DIAGNOSIS OF OVARIAN MALIGNANCY [J].
SMITH, FW ;
CHERRYMAN, GR ;
BAYLISS, AP ;
FULLERTON, WT ;
LAW, ANR ;
ROBERTSON, EM ;
WEIR, J ;
DONALD, RT ;
MALLARD, JR .
MAGNETIC RESONANCE IMAGING, 1988, 6 (03) :225-227