Three-dimensional projection imaging with half the number of projections

被引:16
作者
Boada, FE
Christensen, JD
Gillen, JS
Thulborn, KR
机构
[1] HARVARD UNIV,SCH MED,DEPT PSYCHIAT,BOSTON,MA 02115
[2] MCLEAN HOSP,BRAIN IMAGING CTR,BELMONT,MA 02178
关键词
projection imaging; partial k-space; image reconstruction;
D O I
10.1002/mrm.1910370326
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study demonstrates a sampling scheme for three-dimensional projection imaging with half the number of projections, The angular distribution of projections is designed so that the oversampling of the low spatial frequencies, in tandem with a partial Fourier algorithm, can be used to recreate purposely missing projections, The performance of the sampling scheme and its associated reconstruction algorithm are illustrated with computer-simulated as well as experimental data sets. We find that this technique produces images of comparable quality to the conventional projection imaging scheme. Although a 30% loss of signal-to-noise ratio (SNR) results from its use, the algorithm should prove useful for applications where robustness against motion artifacts and reduced T-2* signal loss are desired.
引用
收藏
页码:470 / 477
页数:8
相关论文
共 20 条
  • [1] LUNG PARENCHYMA - MAGNETIC-SUSCEPTIBILITY IN MR IMAGING
    BERGIN, CJ
    GLOVER, GH
    PAULY, JM
    [J]. RADIOLOGY, 1991, 180 (03) : 845 - 848
  • [2] LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING
    BERGIN, CJ
    PAULY, JM
    MACOVSKI, A
    [J]. RADIOLOGY, 1991, 179 (03) : 777 - 781
  • [3] BOADA F, P SMR 2 ANN SCI M SA, P417
  • [4] BOADA F, 1994, P SMR 2 ANN SCI MED, P792
  • [5] CHESLER D, 1992, P SMRM 11 ANN M BERL, P665
  • [6] B-11 IMAGING WITH A 3-DIMENSIONAL RECONSTRUCTION METHOD
    GLOVER, GH
    PAULY, JM
    BRADSHAW, KM
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (01): : 47 - 52
  • [7] PROJECTION RECONSTRUCTION TECHNIQUES FOR REDUCTION OF MOTION EFFECTS IN MRI
    GLOVER, GH
    PAULY, JM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) : 275 - 289
  • [8] USE OF A PROJECTION RECONSTRUCTION METHOD TO DECREASE MOTION SENSITIVITY IN DIFFUSION-WEIGHTED MRI
    GMITRO, AF
    ALEXANDER, AL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) : 835 - 838
  • [9] A FAST, ITERATIVE, PARTIAL-FOURIER TECHNIQUE CAPABLE OF LOCAL PHASE RECOVERY
    HAACKE, EM
    LINDSKOG, ED
    LIN, W
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1991, 92 (01): : 126 - 145
  • [10] FAST 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING
    IRARRAZABAL, P
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 656 - 662