Dose requirements for UVC disinfection of catheter biofilms

被引:47
作者
Bak, Jimmy [1 ]
Ladefoged, Soren D. [3 ]
Tvede, Michael [2 ]
Begovic, Tanja [1 ]
Gregersen, Annette [2 ]
机构
[1] Tech Univ Denmark, DTU Foton, Roskilde, Denmark
[2] Copenhagen Univ Hosp, Dept Clin Microbiol, Copenhagen, Denmark
[3] Copenhagen Univ Hosp, Nephrol Clin, Copenhagen, Denmark
关键词
biofilm; UVC radiation; catheters; contamination; disinfection; IN-VITRO; INFECTIONS; PREVENTION; LOCK;
D O I
10.1080/08927010802716623
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Bacterial biofilms on permanent catheters are the major sources of infection. Exposure to ultraviolet-C (UVC) light has been proposed as a method for disinfecting the inner surface of catheters. Specification of a UVC-based device for in vivo disinfection is based on the knowledge of the required doses to kill catheter biofilm. Given these doses and the power of available UVC light sources, calculation of the necessary treatment times is then possible. To determine the required doses, contaminated urinary catheters were used as test samples and UVC treated in vitro. Patient catheters (n = 67) were collected and cut into segments of equal size and treated with various UVC doses. After treatment, the biofilm was removed by scraping and quantified by counting colony forming units. Percentage killing rates were determined by calculating ratios between UVC-treated samples and controls (no UVC treatment). Mean killing rates were 89.6% (0.5 min), 98% (2 min), and 99% (60 min). Approximately 99% killing was obtained with a UVC dose of 15 kJ m(-2). This dose, which is about 100 to 1000 times greater than the lethal dose for planktonic cells, is expected to be the maximum dose required to maintain newly inserted catheters free of contamination. The combination of high doses required to kill mature biofilm and the limited effect of current UVC light sources result in a relative long treatment time (similar to 60 min). If a UVC-based method is to be of practical use for disinfection of catheters in the clinic, repeated preventive treatments should be carried out on newly inserted catheters.
引用
收藏
页码:289 / 296
页数:8
相关论文
共 22 条
[1]   An engineering approach to the control of Mycobacterium tuberculosis and other airborne pathogens:: a UK hospital based pilot study [J].
Beggs, CB ;
Kerr, KG ;
Donnelly, JK ;
Sleigh, PA ;
Mara, DD ;
Cairns, G .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2000, 94 (02) :141-146
[2]  
BOUDREAUX CP, 2002, Patent No. 6461569
[3]   MICROBIAL BIOFILMS [J].
COSTERTON, JW ;
LEWANDOWSKI, Z ;
CALDWELL, DE ;
KORBER, DR ;
LAPPINSCOTT, HM .
ANNUAL REVIEW OF MICROBIOLOGY, 1995, 49 :711-745
[4]   Current concepts - Treatment of infections associated with surgical implants [J].
Darouiche, RO .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (14) :1422-1429
[5]  
ECKHARDT R, 2002, Patent No. 02102421
[6]   THE NATIONWIDE NOSOCOMIAL INFECTION-RATE - A NEW NEED FOR VITAL STATISTICS [J].
HALEY, RW ;
CULVER, DH ;
WHITE, JW ;
MORGAN, WM ;
EMORI, TG .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1985, 121 (02) :159-167
[7]   Diagnosis and management of long-term central venous catheter infections [J].
Hall, K ;
Farr, B .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (04) :327-334
[8]   Effect of vancomycin and rifampicin on meticillin-resistant Staphylococcus aureus biofilms [J].
Jones, SM ;
Morgan, M ;
Humphrey, TJ ;
Lappin-Scott, H .
LANCET, 2001, 357 (9249) :40-41
[9]   Taurolidine lock: The key to prevention of recurrent catheter-related bloodstream infections [J].
Jurewitsch, B ;
Jeejeebhoy, KN .
CLINICAL NUTRITION, 2005, 24 (03) :462-465
[10]   Device physics - A bug-beating [J].
Khan, A .
NATURE, 2006, 441 (7091) :299-299