Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging

被引:85
作者
Brau, ACS [1 ]
Brittain, JH [1 ]
机构
[1] GE Healthcare, Appl Sci Lab W, Menlo Pk, CA 94025 USA
关键词
self-navigated; self-gated; motion detection; respiratory motion; cardiac motion; abdominal imaging;
D O I
10.1002/mrm.20785
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Patient motion remains a primary obstacle to diagnostic image quality, especially in the abdomen, despite the existence of various motion artifact reduction techniques. This work prosents a self-navigated motion detection method that can be generalized for most pulse sequences and k-space trajectories. Motion information is extracted directly from raw MR data, requiring no additional gradient or RF pulses, no physiologic monitoring equipment, and minimal-if any-impact on scan time. Initial feasibility results with a two-dimensional gradient echo sequence are shown in phantom studies and in vivo volunteer abdominal studies, demonstrating the sensitivity of the method to both respiratory motion and cardiovascular pulsatility. Prospectively gated images were acquired using the self-navigated data to synchronize image acquisition with motion. These preliminary results suggest that the self-navigated method is a promising technique for reducing motion artifacts in clinical abdominal and cardiac applications.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 22 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]   Automated rectilinear self-gated cardiac cine imaging [J].
Crowe, ME ;
Larson, AC ;
Zhang, Q ;
Carr, J ;
White, RD ;
Li, DB ;
Simonetti, OP .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :782-788
[3]   Prospective navigator correction of image position for coronary MR angiography [J].
Danias, PG ;
McConnell, MV ;
Khasgiwala, VC ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
RADIOLOGY, 1997, 203 (03) :733-736
[4]   ULTRASOUND QUANTITATION OF RESPIRATORY ORGAN MOTION IN THE UPPER ABDOMEN [J].
DAVIES, SC ;
HILL, AL ;
HOLMES, RB ;
HALLIWELL, M ;
JACKSON, PC .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (803) :1096-1102
[5]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[6]   Self-navigated spiral fMRI: Interleaved versus single-shot [J].
Glover, GH ;
Lai, S .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) :361-368
[7]  
HINKS S, 1988, P ANN M SMRM, P744
[8]   REDUCTION OF SIGNAL FLUCTUATION IN FUNCTIONAL MRI USING NAVIGATOR ECHOES [J].
HU, XP ;
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :495-503
[9]   RETROSPECTIVE ESTIMATION AND CORRECTION OF PHYSIOLOGICAL FLUCTUATION IN FUNCTIONAL MRI [J].
HU, XP ;
LE, TH ;
PARRISH, T ;
ERHARD, P .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :201-212
[10]   EXTRACTION OF CARDIAC AND RESPIRATORY MOTION CYCLES BY USE OF PROJECTION DATA AND ITS APPLICATION TO NMR IMAGING [J].
KIM, WS ;
MUN, CW ;
KIM, DJ ;
CHO, ZH .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :25-37