Metallothionein isoforms separation and cadmium speciation by capillary electrophoresis with ultraviolet and quadrupole-inductively coupled plasma mass spectrometric detection

被引:37
作者
Alvarez-Llamas, G [1 ]
de la Campa, MRF [1 ]
Sanz-Medel, A [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
metallothioneins; cadmium speciation; capillary electrophoresis; quadrupole-inductively coupled plasma mass spectrometry; nebulisers;
D O I
10.1016/S0003-2670(01)01315-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A complete characterisation of metallothioneins (MTs) in biological systems requires first an optimal separation of the different isoforms and sub-isoforms present. A method for the adequate separation of rabbit liver MT1 and MT2 mixtures by capillary zone electrophoresis (CZE) with UV detection is developed here. Different experimental conditions affecting both, peak shape and resolution achieved, are investigated in detail. Thus, the influence of the composition, ionic strength and pH of the buffer solution, and the separation voltage, have been studied. In order to improve the resolution between sub-isoforms, the electroosmotic flow has been also changed and its effect investigated by adding organic modifiers. Analytical performance characteristics are evaluated: calibration graphs were linear between 70 and 205 mug ml(-1) for MT1 and between 83 and 242 mug ml(-1) for MT2, while the detection limits were 4 and 3 mug ml(-1), respectively. Speciation of the metal-MTs compounds has been accomplished by the coupling CZE-ICP-MS by means of different nebulisers: a conventional concentric Meinhard nebuliser, a Babington type one and a high efficiency nebuliser (HEN). Finally, real sample MTs analyses have been carried out in mussel hepatopancreas cytosols, previously exposed to a metal enriched environment. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:105 / 119
页数:15
相关论文
共 42 条
[1]   Evaluation of a microconcentric nebulizer and its suction effect in a capillary electrophoresis interface with inductively coupled plasma mass spectrometry [J].
B'Hymer, C ;
Day, JA ;
Caruso, JA .
APPLIED SPECTROSCOPY, 2000, 54 (07) :1040-1046
[2]   The use of sol-gel frits to minimize suction effects in capillary electrophoresis-nebulizer interfaces for plasma spectrometry [J].
B'Hymer, C ;
Sutton, RMC ;
Sutton, KL ;
Caruso, JA .
ANALYTICAL COMMUNICATIONS, 1999, 36 (9-10) :349-353
[3]   Comparison of a cross-flow and microconcentric nebulizer for chemical speciation measurements using CZE-ICP-MS [J].
Baker, SA ;
Miller-Ihli, NJ .
APPLIED SPECTROSCOPY, 1999, 53 (04) :471-478
[4]   Strategies for the qualitative and quantitative analysis of metallothionein isoforms by capillary electrophoresis [J].
Beattie, JH .
TALANTA, 1998, 46 (02) :255-270
[5]   Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation [J].
Bendahl, L ;
Gammelgaard, B ;
Jons, O ;
Farver, O ;
Hansen, SH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (01) :38-42
[6]  
BLANCO CC, 1998, ELECTROFORESIS CAPIL, P263
[7]   Interface for capillary electrophoresis coupled with inductively coupled plasma atomic emission spectrometry [J].
Chan, YY ;
Chan, WT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :141-149
[8]  
da Rocha MS, 2000, J ANAL ATOM SPECTROM, V15, P513
[9]   A comparison of capillary electrophoresis using indirect UV absorbance and ICP-MS detection with a self-aspirating nebulizer interface [J].
Day, JA ;
Sutton, KL ;
Soman, RS ;
Caruso, JA .
ANALYST, 2000, 125 (05) :819-823
[10]   Improved separation of rabbit liver metallothioneins by FPLC-ICP-MS:: a comparison with the conventional anion-exchange chromatography [J].
Ferrarello, C ;
de la Campa, MRF ;
Infante, HG ;
Sánchez, MLF ;
Sanz-Medel, A .
ANALUSIS, 2000, 28 (05) :351-357