Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation

被引:94
作者
Bendahl, L [1 ]
Gammelgaard, B [1 ]
Jons, O [1 ]
Farver, O [1 ]
Hansen, SH [1 ]
机构
[1] Royal Danish Sch Pharm, Dept Analyt & Pharmaceut Chem, DK-2100 Copenhagen, Denmark
关键词
D O I
10.1039/b007137o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A demountable direct injection high efficiency nebulizer operating at low sample uptake rates was developed and used for coupling of capillary electrophoresis (CE) with inductively coupled plasma mass spectrometry (ICP-MS). When the nebulizer was used for continuous sample introduction, detection limits of 20 and 1 ng L-1 were obtained for Se-82 and Rh-103, respectively, at sample uptake rates of 10-30 muL min(-1), based on three times the standard deviation of blank solution (3 sigma (b), n = 10). The nebulizer was used as part of the interface for coupling of CE with ICP-MS and applied for speciation of aqueous selenium standards. The interface was operated in the self-aspirating mode with a sheath liquid uptake of 10 muL min(-1). The CE-ICP-MS system resulted in baseline separation of selenate, selenite, selenocystine and selenomethionine within a total analysis time of 5.4 min. Detection limits were in the sub mug Se L-1 range, corresponding to absolute detection limits in the range 25-125 fg selenium. Repeatability (n = 6) expressed as relative standard deviations with respect to migration times, peak heights and peak areas were better than 1.6, 6.7 and 6.0%, respectively.
引用
收藏
页码:38 / 42
页数:5
相关论文
共 31 条
[1]   Enzymatic digestion for the determination of trace elements in blood serum by inductively coupled plasma mass spectrometry [J].
AbouShakra, FR ;
Rayman, MP ;
Ward, NI ;
Hotton, V ;
Bastian, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) :429-433
[2]   The use of sol-gel frits to minimize suction effects in capillary electrophoresis-nebulizer interfaces for plasma spectrometry [J].
B'Hymer, C ;
Sutton, RMC ;
Sutton, KL ;
Caruso, JA .
ANALYTICAL COMMUNICATIONS, 1999, 36 (9-10) :349-353
[3]   Interface for capillary electrophoresis coupled with inductively coupled plasma atomic emission spectrometry [J].
Chan, YY ;
Chan, WT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :141-149
[4]  
da Rocha MS, 2000, BIOMED CHROMATOGR, V14, P6
[5]   A comparison of capillary electrophoresis using indirect UV absorbance and ICP-MS detection with a self-aspirating nebulizer interface [J].
Day, JA ;
Sutton, KL ;
Soman, RS ;
Caruso, JA .
ANALYST, 2000, 125 (05) :819-823
[6]   Determination of selenium in urine by inductively coupled plasma mass spectrometry: interferences and optimization [J].
Gammelgaard, B ;
Jons, O .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (05) :867-874
[7]  
HASUNUMA R, 1993, B ENVIRON CONTAM TOX, V50, P19, DOI 10.1007/BF00196535
[8]   Effect of laminar flow in capillary electrophoresis: Model and experimental results on controlling analysis time and resolution with inductively coupled plasma mass spectrometry detection [J].
Kinzer, JA ;
Olesik, JW ;
Olesik, SV .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3250-3257
[9]   An evaluation of ultrasonic nebulizers as interfaces for capillary electrophoresis of inorganic anions and cations with inductively coupled plasma mass spectrometric detection [J].
Kirlew, PW ;
Castillano, MTM ;
Caruso, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (02) :221-237
[10]   Separation of selenium-containing proteins in human and mouse plasma using tandem high-performance liquid chromatography columns coupled with inductively coupled plasma-mass spectrometry [J].
Koyama, H ;
Omura, K ;
Ejima, A ;
Kasanuma, Y ;
Watanabe, C ;
Satoh, H .
ANALYTICAL BIOCHEMISTRY, 1999, 267 (01) :84-91