Performance characteristics of scintillators for use in an electronic neutron imaging system for neutron radiography

被引:15
作者
Brenizer, JS
Berger, H
Stebbings, CT
Gillies, GT
机构
[1] IND QUAL INC,GAITHERSBURG,MD 20877
[2] UNIV VIRGINIA,HLTH SCI CTR,SCH ENGN & APPL SCI,DEPT MECH AEROSP & NUCL ENGN,CHARLOTTESVILLE,VA 22908
[3] UNIV VIRGINIA,HLTH SCI CTR,DEPT BIOMED ENGN,CHARLOTTESVILLE,VA 22908
关键词
D O I
10.1063/1.1148299
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The response of several different scintillator screens to beams of slow neutrons has been investigated using charge-coupled device (CCD)-based and nuvicon imaging systems. The goal of the effort has been to design and develop an electronic neutron imager compatible for use with a neutron radiography system driven by an accelerator that generates intensities of approximate to 10(6) neutrons cm(-2)s(-1). The experimental results demonstrated that the LiF/ZnS class of scintillators used with a CCD camera could provide near-real-time images with a dynamic range (i.e., a functional span of optical intensities) of greater than or equal to 10(3) and spatial resolution of 2.5 line pairs mm(-1). Full details of the experimental arrangements are presented, along with discussions of the scintillator properties, the results of their use in thermal neutron beams, and an assessment of the performance characteristics of the various imaging techniques that were employed. (C) 1997 American Institute of Physics.
引用
收藏
页码:3371 / 3379
页数:9
相关论文
共 31 条
[21]  
*LEV HILL LAB LTD, FLUOR SCINT PROD IND
[22]  
LEVERENZ HW, 1950, INTRO LUMINESCENCE S, P196
[23]   WATER DIFFUSION PROFILE MEASUREMENTS IN EPOXY USING NEUTRON RADIOGRAPHY [J].
LINDSAY, JT ;
MATSUBAYASHI, M ;
ISLAM, MN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :149-151
[24]  
LINDSAY JT, 1983, THESIS U MISSOURI
[25]   Digital image processing of images obtained with a Pu-Be (similar to 10(7)) neutron source [J].
Panchal, CG ;
Sinha, A ;
Bhawe, BD ;
Shyam, A ;
Srinivasan, M ;
Joshi, VM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (08) :2775-2779
[26]   NEUTRON RADIOGRAPHIC MEASUREMENT OF POROSITY OF CRYSTALLINE ROCK SAMPLES - A FEASIBILITY STUDY [J].
PLEINERT, H ;
DEGUELDRE, C .
JOURNAL OF CONTAMINANT HYDROLOGY, 1995, 19 (01) :29-46
[27]  
RAUSCH C, IN PRESS J NEUTRON R
[28]  
ROSE A, 1970, APPL SOLID STATE PHY, P115
[29]   REAL-TIME NEUTRON RADIOGRAPHY SYSTEM PERFORMANCE - MEASUREMENTS AND METHODS [J].
SULCOSKI, MF ;
TOBIN, KW ;
BRENIZER, JS .
NUCLEAR TECHNOLOGY, 1988, 82 (03) :355-362
[30]  
TAKENAKA N, 1995, FUSION ENG DES, V27, P607, DOI 10.1016/0920-3796(95)90175-2