Spiral CT angiography of the pulmonary circulation

被引:184
作者
Remy-Jardin, M [1 ]
Remy, J [1 ]
机构
[1] Hop Calmette, Dept Radiol, F-59037 Lille, France
关键词
computed tomography (CT); angiography; helical; volume rendering; embolism; pulmonary; lung neoplasms; CT; pulmonary arteries; pulmonary veins; state-of-art reviews;
D O I
10.1148/radiology.212.3.r99se02615
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spiral computed tomographic (CT) angiography of the pulmonary circulation has emerged recently as a potential useful diagnostic method for the evaluation of the pulmonary circulation. As a minimally, invasive examination, this technique is becoming widely available and has progressively replaced conventional and digital pulmonary angiography as the standard diagnostic imaging modality of the pulmonary circulation. The purpose of this review is to capture the current state of the art of the technical aspects of spiral CT angiography, with special emphasis on the postprocessing techniques currently available. As CT is responsible for a considerable part of the medical radiation dose applied to the population, the current trends for dose saving will also be emphasized. With regard to the clinical applications of spiral CT angiography, its introduction into the diagnostic work-up of pulmonary embolism has considerably modified the diagnostic algorithms. Our 8-year review of the literature presented herein is expected to provide the readers with a basis for formulating an informed opinion on this topic. In addition, a large number of congenital and acquired disorders of the pulmonary circulation are also relevant to this technique, and these indications are discussed in the context of the corresponding therapeutic options. Owing to the multiple possibilities inherent to this technique, spiral CT has the potential for cost savings without reduction in image quality or diagnostic accuracy.
引用
收藏
页码:615 / 636
页数:22
相关论文
共 132 条
  • [111] SUTTON GC, 1977, BRIT HEART J, V39, P1135
  • [112] CT angiography of carotid bifurcation: Artifacts and pitfalls in shaded-surface display
    Takahashi, M
    Ashtari, M
    Papp, Z
    Patel, M
    Goldstein, J
    Maguire, WM
    Eacobacci, T
    Khan, A
    Herman, PG
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (03) : 813 - 817
  • [113] CLOT IN THE PULMONARY-ARTERY AFTER PNEUMONECTOMY
    TAKAHASHI, T
    YOKOI, K
    MORI, K
    MIYAZAWA, N
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (05) : 1110 - 1110
  • [114] 2 CASES OF SCIMITAR VARIANT
    TAKEDA, S
    IMACHI, T
    ARIMITSU, K
    MINAMI, M
    HAYAKAWA, M
    [J]. CHEST, 1994, 105 (01) : 292 - 293
  • [115] Utility of CT scan evaluation for predicting pulmonary hypertension in patients with parenchymal lung disease
    Tan, RT
    Kuzo, R
    Goodman, LR
    Siegel, R
    Haasler, GB
    Presberg, KW
    [J]. CHEST, 1998, 113 (05) : 1250 - 1256
  • [116] DYNAMIC CONTRAST ENHANCEMENT OF ASBESTOS-RELATED PULMONARY PSEUDOTUMORS
    TAYLOR, PM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (731) : 1070 - 1072
  • [117] PULMONARY-EMBOLISM - DIAGNOSIS WITH CONTRAST-ENHANCED ELECTRON-BEAM CT AND COMPARISON WITH PULMONARY ANGIOGRAPHY
    TEIGEN, CL
    MAUS, TP
    SHEEDY, PF
    STANSON, AW
    JOHNSON, CM
    BREEN, JF
    MCKUSICK, MA
    [J]. RADIOLOGY, 1995, 194 (02) : 313 - 319
  • [118] PULMONARY-EMBOLISM - DIAGNOSIS WITH ELECTRON-BEAM CT
    TEIGEN, CL
    MAUS, TP
    SHEEDY, PF
    JOHNSON, CM
    STANSON, AW
    WELCH, TJ
    [J]. RADIOLOGY, 1993, 188 (03) : 839 - 845
  • [119] CT AND MR IMAGING OF PARTIAL ANOMALOUS PULMONARY VENOUS RETURN TO THE AZYGOUS VEIN
    THORSEN, MK
    ERICKSON, SJ
    MEWISSEN, MW
    YOUKER, JE
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) : 1007 - 1009
  • [120] OXYGEN AND TC-99M-MAA SHUNT ESTIMATIONS IN PATIENTS WITH PULMONARY ARTERIOVENOUS-MALFORMATIONS - EFFECTS OF CHANGES IN POSTURE AND LUNG-VOLUME
    UEKI, J
    HUGHES, JMB
    PETERS, AM
    BELLINGAN, GJ
    MOHAMMED, MAM
    DUTTON, J
    USSOV, W
    KNIGHT, D
    GLASS, D
    [J]. THORAX, 1994, 49 (04) : 327 - 331