Reliability of the lumbar flexion, lumbar extension, and passive straight leg raise test in normal populations embedded within a complete physical examination

被引:34
作者
Hunt, DG
Zuberbier, OA
Kozlowski, AJ
Robinson, J
Berkowitz, J
Schultz, IZ
Milner, RA
Crook, JM
Turk, DC
机构
[1] Univ British Columbia, Dept Educ & Counseling Psychol & Special Practice, Vancouver, BC V6T 1Z4, Canada
[2] Univ British Columbia, Dept Family Practice, Vancouver, BC V6T 1Z4, Canada
[3] Univ British Columbia, Dept Surg, Vancouver, BC V6T 1Z4, Canada
[4] Workers Compensat Board British Columbia, Richmond, BC, Canada
[5] Univ Washington, Ctr Multidisciplinary Pain, Seattle, WA 98195 USA
[6] McMaster Univ, Fac Hlth Sci, Hamilton, ON L8S 4L8, Canada
[7] Univ Washington, Dept Anesthesiol & Pain Res, Seattle, WA 98195 USA
关键词
impairment; lumbar; range of motion; inclinometry; reproducibility of results; observer variation; physical examination; low back pain; lumbosacral region;
D O I
10.1097/00007632-200112150-00018
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. The study measured the reliability of the passive straight leg raise (SLR) test and lumbar range of motion (LROM) tests measured as continuous variables embedded within a comprehensive physical examination. Objectives. To determine the reliability of the SLR and LROM test scores when they are measured with a Cybex electronic inclinometer (Lumex, Inc., New York, NY) within a physical examination. Summary of Background Data. Good published empirical reliability exists for the Cybex and for SLR and LROM tests when the measurements are taken in isolation from other physical examination procedures. Reliability of the Cybex for continuous SLR and LROM measurement within a physical examination has not been assessed, however. Methods. Forty-five participants were seen by one of two physician/physiotherapist teams, Participants were examined by both team members. The first examiner conducted the first tests and retested 1 week later (intrarater reliability). The second examined the participants the day after their first appointment (inter-rater reliability). Results. Only two scores showed substantial reliability (defined as r > 0.60). These scores were left (r = 0.81) and right (r = 0.79) SLR intrarater reliability. All other scores fell below the specified cutoff. Conclusions. SLR and LROM scores used clinically are collected during comprehensive physical examinations. Most scores gathered under these conditions were not reliable. These findings have implications for the use of clinically derived SLR and LROM scores.
引用
收藏
页码:2714 / 2718
页数:5
相关论文
共 38 条
[1]  
ALARANTA H, 1994, SCAND J REHABIL MED, V26, P147
[2]  
*AM MED ASS, 1993, GUID EV PERM IMP, P94
[3]  
[Anonymous], 1998, PHYSIOTHER CAN
[4]  
Bo K, 1997, SCAND J MED SCI SPOR, V7, P140
[5]   LOW-BACK IMPAIRMENT RATING PRACTICES OF ORTHOPEDIC SURGEONS [J].
BRAND, RA ;
LEHMANN, TR .
SPINE, 1983, 8 (01) :75-78
[6]  
BRIEG A, 1979, SPINE, V4, P242
[7]   Reliability of three lumbar sagittal motion measurement methods: Surface inclinometers [J].
Chen, SPC ;
Samo, DG ;
Chen, EH ;
Crampton, AR ;
Conrad, KM ;
Egan, L ;
Mitton, J .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1997, 39 (03) :217-223
[8]  
CHIARELLO CM, 1993, ARCH PHYS MED REHAB, V74, P32
[9]   MOTION OF THE LUMBAR SPINE - RELIABILITY OF 2 MEASUREMENT TECHNIQUES [J].
DILLARD, J ;
TRAFIMOW, J ;
ANDERSSON, GBJ ;
CRONIN, K .
SPINE, 1991, 16 (03) :321-324
[10]   INDUCED PAIN PATTERNS ON PASSIVE STRAIGHT-LEG RAISING IN LOWER LUMBAR-DISK PROTRUSION - PROSPECTIVE CLINICAL, MYELOGRAPHIC AND OPERATIVE STUDY IN 50 PATIENTS [J].
EDGAR, MA ;
PARK, WM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1974, B 56 (04) :658-667