Electrical conductivity imaging via contactless measurements

被引:56
作者
Gençer, NG [1 ]
Tek, MN [1 ]
机构
[1] Middle E Tech Univ, Dept Elect & Elect Engn, TR-06531 Ankara, Turkey
关键词
electrical conductivity; finite-element method (FEM); magnetic induction; medical imaging;
D O I
10.1109/42.790461
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A new imaging modality is introduced to image electrical conductivity of biological tissues via contactless measurements. This modality uses magnetic excitation to induce currents inside the body and measures the magnetic fields of the induced currents. In this study, the mathematical basis of the methodology is analyzed and numerical models are developed to simulate the imaging system. The induced currents are expressed using the (A) over right arrow-phi formulation of the electric field where (A) over right arrow is the magnetic vector potential and phi is the scalar potential function. It is assumed that (A) over right arrow describes the primary magnetic vector potential that exists in the absence of the body. This assumption considerably simplifies the solution of the secondary magnetic fields caused by induced currents. In order to solve phi for objects of arbitrary conductivity distribution a three-dimensional (3-D) finite-element method (FEM) formulation is employed. A specific 7 x 7-coil system is assumed nearby the upper surface of a 10 x 10 x 5-cm conductive body. A sensitivity matrix, which relates the perturbation in measurements to the conductivity perturbations, is calculated. Singular-value decomposition of the sensitivity matrix shows various characteristics of the imaging system. Images are reconstructed using 500 voxels in the image domain, with truncated pseudoinverse. The noise level is assumed to produce a representative signal-to-noise ratio (SNR) of 80 dB. It is observed that it is possible to identify voxel perturbations (of volume 1 cm(3)) at 2 cm depth. However, resolution gradually decreases for deeper conductivity perturbations.
引用
收藏
页码:617 / 627
页数:11
相关论文
共 44 条
[1]  
[Anonymous], 1961, Principles and Applications of Electromagnetic Fields
[2]  
[Anonymous], CLIN PHYS PHYSL MEAS
[3]   APPLIED POTENTIAL TOMOGRAPHY [J].
BARBER, DC ;
BROWN, BH .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (09) :723-733
[4]   Imaging with electricity: Report of the European Concerted Action on Impedance Tomography [J].
Boone, K ;
Barber, D ;
Brown, B .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1997, 21 (06) :201-232
[5]   IMAGING OF CORTICAL SPREADING DEPRESSION OF EIT - IMPLICATIONS FOR LOCALIZATION OF ELIEPTIC FOCI [J].
BOONE, K ;
LEWIS, AM ;
HOLDER, DS .
PHYSIOLOGICAL MEASUREMENT, 1994, 15 :A189-A198
[6]  
Conway J, 1987, Clin Phys Physiol Meas, V8 Suppl A, P141, DOI 10.1088/0143-0815/8/4A/018
[7]   EEG localization accuracy improvements using realistically shaped head models [J].
Cuffin, BN .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (03) :299-303
[8]   LOCALISATION OF CARDIAC RELATED IMEDANCE CHANGES IN THE THORAX. [J].
Eyuboglu, B.M. ;
Brown, B.H. ;
Barber, D.C. ;
Seagar, A.D. .
Clinical Physics and Physiological Measurement, 1986, 8 suppl A :167-173
[9]   IMPEDANCE IMAGING USING INDUCED CURRENTS [J].
FREESTON, IL ;
TOZER, RC .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 :A257-A266
[10]   Electrical impedance tomography: Induced-current imaging achieved with a multiple coil system [J].
Gencer, NG ;
Ider, YZ ;
Williamson, SJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (02) :139-149