Resistance of Ag(I) implanted polypyrrole-based anion ise to cation interferences

被引:12
作者
Chou, SH [1 ]
Rau, JR [1 ]
Chen, SC [1 ]
机构
[1] FU JEN CATHOLIC UNIV,DEPT CHEM,TAIPEI,TAIWAN
关键词
polypyrrole; Ag(I)-ppy; resistance to cation poisoning; electrode poisoning;
D O I
10.1016/S0013-4686(96)00413-6
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The polypyrrole-based anion selective electrode was reported to be susceptible to interferences from cations as well as anions. However, if the aggressively interfering Ag(I) is implanted during the electrode fabrication, the ise can be inoculated against cation interferences from Cu(II) or Pb(II) of less aggressive cations. In the extreme case of Ag(I) poisoning in measurement, the electrode can be rejuvenated by a simple electrochemical procedure. However, the selectivities of the modified ise will in general differ from those of the virgin ise. (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:2313 / 2317
页数:5
相关论文
共 30 条
[21]  
RAKHMANKO EM, 1994, J ANAL CHEM+, V49, P414
[22]   Study of Au(I)-polypyrrole interaction [J].
Rau, JR ;
Lee, JC ;
Chen, SC .
SYNTHETIC METALS, 1996, 79 (01) :69-74
[23]   CHARACTERIZATION OF A POLYPYRROLE MICROSENSOR FOR NITRATE AND NITRITE IONS [J].
RAU, JR ;
CHEN, SC ;
SUN, HW .
ELECTROCHIMICA ACTA, 1994, 39 (18) :2773-2779
[24]  
RUSSELL D, 1989, J ELECTROCHEM SOC, V136, P2769
[25]   ION-EXCHANGE MECHANISM OF POLYPYRROLE AND POLY-N-METHYLPYRROLE WITH TOSLYLATE AS DOPING ANION - AN ELECTROCHEMICAL QUARTZ CRYSTAL MICROBALANCE STUDY [J].
SCHMIDT, VM ;
HEITBAUM, J .
ELECTROCHIMICA ACTA, 1993, 38 (2-3) :349-356
[26]   ELECTROCHEMISTRY OF CONDUCTIVE POLYMERS .6. DEGRADATION REACTION-KINETICS OF POLYANILINE STUDIED BY ROTATING-RING-DISK ELECTRODE TECHNIQUES [J].
STILWELL, DE ;
PARK, SM .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (03) :688-698
[27]   FLOW-INJECTION APPROACH FOR THE DETERMINATION OF THE DYNAMIC-RESPONSE CHARACTERISTICS OF ION-SELECTIVE ELECTRODES .2. APPLICATION TO TUBULAR SOLID-STATE IODIDE ELECTRODE [J].
TOTH, K ;
LINDNER, E ;
PUNGOR, E ;
KOLEV, SD .
ANALYTICA CHIMICA ACTA, 1990, 234 (01) :57-65
[28]   CRYSTAL-FACE-SPECIFIC RESPONSE OF A SINGLE-CRYSTAL CADMIUM-SULFIDE BASED ION-SELECTIVE ELECTRODE [J].
UOSAKI, K ;
SHIGEMATSU, Y ;
KITA, H ;
UMEZAWA, Y ;
SOUDA, R .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1980-1983
[29]   PREPARATION AND APPLICATION OF CONDUCTING POLYMERS CONTAINING CHEMICALLY ACTIVE COUNTERIONS FOR ANALYTICAL PURPOSES [J].
WALLACE, GG ;
LIN, YP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 247 (1-2) :145-156
[30]   FLOW-INJECTION ANALYSIS OF ELECTROINACTIVE ANIONS AT A POLYANILINE ELECTRODE [J].
YE, JN ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1988, 60 (18) :1979-1982