ESR solid state dosimetry: Behaviour of various amino acids and blend preparation procedures

被引:18
作者
Bartolotta, A
Brai, M
Caputo, V
De Caro, V
Giannola, LI
Rap, R
Teri, G
机构
[1] Univ Palermo, Ist Farmacochim, I-90123 Palermo, Italy
[2] Univ Palermo, Ist Biocomunicaz, I-90133 Palermo, Italy
[3] Serv Fis Sanitaria, Palermo, Italy
[4] Univ Palermo, Dipartimento Chim & Tecnol Farmaceut, I-90133 Palermo, Italy
关键词
D O I
10.1093/oxfordjournals.rpd.a032742
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In several laboratories all around the world, election spin resonance (ESR) dosimetry is a well-established reference dosimetric system in industrial applications of ionising radiation, and its use is also proposed in radiation therapy and accident dosimetry. In the present experimental investigation preparation procedures of alanine-polyethylene solid state dosemeters (SSD) with optimised characteristics were defined, both modifying the commonly used blend composition and preparation, and choosing the best ESR spectra recording conditions; some other amino acids that could be alternatives to alanine in obtaining ESR dosemeters with better performances than alanine ones were also tested. Results obtained up to now (the research is still under way) confirm that alanine seems to be the most suitable material for ESR dosimetry. Methods to improve reproducibility are also discussed.
引用
收藏
页码:293 / 296
页数:4
相关论文
共 13 条
[1]  
[Anonymous], 1995, ANN BOOK ASTM STAND, DOI DOI 10.1520/2002C
[2]  
ARBER JM, 1991, APPL RADIAT ISOTOPES, V42, P665, DOI 10.1016/0883-2889(91)90037-2
[3]   SOURCES OF UNCERTAINTY IN THERAPY LEVEL ALANINE DOSIMETRY [J].
BARTOLOTTA, A ;
FATTIBENE, P ;
ONORI, S ;
PANTALONI, M ;
PETETTI, E .
APPLIED RADIATION AND ISOTOPES, 1993, 44 (1-2) :13-17
[4]   Orientation effects on ESR analysis of alanine-polymer dosimeters [J].
Kojima, T ;
Kashiwazaki, S ;
Tachibana, H ;
Tanaka, R ;
Desrosiers, MF ;
McLaughlin, WL .
APPLIED RADIATION AND ISOTOPES, 1995, 46 (12) :1407-1411
[5]   Alanine-polystyrene dosimeters prepared by injection moulding [J].
Kojima, T ;
Kashiwazaki, S ;
Zhang, Y .
APPLIED RADIATION AND ISOTOPES, 1997, 48 (07) :965-968
[6]  
KOJIMA T, 1986, APPL RADIAT ISOTOPES, V37, P517
[7]   Complex time dependence of the EPR signal of irradiated L-alpha-alanine [J].
Nagy, VY ;
Desrosiers, MF .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (08) :789-793
[8]   Proton response of alanine based pellets and films [J].
Onori, S ;
DErrico, F ;
DeAngelis, C ;
Egger, E ;
Fattibene, P ;
Janovsky, I .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) :1201-1204
[9]  
Poole C.P. J., 1971, RELAXATION MAGNETIC
[10]   CALIBRATION NETWORK BASED ON ALANINE ESR DOSIMETRY [J].
REGULLA, D ;
BARTOLOTTA, A ;
DEFFNER, U ;
ONORI, S ;
PANTALONI, M ;
WIESER, A .
APPLIED RADIATION AND ISOTOPES, 1993, 44 (1-2) :23-31