Retrospective: Radiation damage and its associated "Information Limitations"

被引:62
作者
Glaeser, Robert M. [1 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Div Life Sci, Berkeley, CA 94720 USA
关键词
electron microscopy; radiation damage; biological specimens; beam-induced movement;
D O I
10.1016/j.jsb.2008.06.001
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The fact that radiation damage would limit the usefulness of electron microscopy with biological specimens was a concern in the earliest days of the field. Good estimates of what that limitation must be can be made by using Rose's empirical relationship between the inherent image contrast, the exposure used to record an image, and the smallest feature size that is detectable. Such estimates show that it is necessary to average many images in order to obtain statistically well-defined data at high resolution. Structures are now routinely obtained by averaging large numbers of shot-noise limited images, and some of these extend to atomic resolution. The signal level in current images is nevertheless far below what physics would allow it to be. A possible explanation is that beam-induced movement limits the quality of images recorded by electron microscopy. For specimens embedded in vitreous ice, beam-induced movement can even be severe enough to limit the resolution achieved during tomographic reconstruction. The fact that very high-quality images can nevertheless be obtained, although only unpredictably, suggests that it may be possible to devise new techniques of specimen preparation and/or data collection that at least partially overcome beam-induced movement. If so, the need for image averaging would be correspondingly reduced. Published by Elsevier Inc.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 48 条
  • [1] [Anonymous], 1966, J MICROSC-PARIS
  • [2] Practical considerations for high spatial and temporal resolution dynamic transmission electron microscopy
    Armstrong, Michael R.
    Boyden, Ken
    Browning, Nigel D.
    Campbell, Geoffrey H.
    Colvin, Jeffrey D.
    DeHope, William J.
    Frank, Alan M.
    Gibson, David J.
    Hartemann, Fred
    Kim, Judy S.
    King, Wayne E.
    LaGrange, Thomas B.
    Pyke, Ben J.
    Reed, Bryan W.
    Shuttlesworth, Richard M.
    Stuart, Brent C.
    Torralva, Ben R.
    [J]. ULTRAMICROSCOPY, 2007, 107 (4-5) : 356 - 367
  • [3] CONTRAST ANALYSIS OF CRYO-IMAGES OF N-PARAFFIN RECORDED AT 400 KV OUT TO 2.1 A RESOLUTION
    BRINK, J
    CHIU, W
    [J]. JOURNAL OF MICROSCOPY, 1991, 161 : 279 - 295
  • [4] Femtosecond diffractive imaging with a soft-X-ray free-electron laser
    Chapman, Henry N.
    Barty, Anton
    Bogan, Michael J.
    Boutet, Sebastien
    Frank, Matthias
    Hau-Riege, Stefan P.
    Marchesini, Stefano
    Woods, Bruce W.
    Bajt, Sasa
    Benner, Henry
    London, Richard A.
    Ploenjes, Elke
    Kuhlmann, Marion
    Treusch, Rolf
    Duesterer, Stefan
    Tschentscher, Thomas
    Schneider, Jochen R.
    Spiller, Eberhard
    Moeller, Thomas
    Bostedt, Christoph
    Hoener, Matthias
    Shapiro, David A.
    Hodgson, Keith O.
    Van der Spoel, David
    Burmeister, Florian
    Bergh, Magnus
    Caleman, Carl
    Huldt, Goesta
    Seibert, M. Marvin
    Maia, Filipe R. N. C.
    Lee, Richard W.
    Szoeke, Abraham
    Timneanu, Nicusor
    Hajdu, Janos
    [J]. NATURE PHYSICS, 2006, 2 (12) : 839 - 843
  • [5] CHIU W, 1986, Journal of Microscopy (Oxford), V141, P385
  • [6] Dose tolerance at helium and nitrogen temperatures for whole cell electron tomography
    Comolli, LR
    Downing, KH
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2005, 152 (03) : 149 - 156
  • [7] Frank J., 2006, Three-Dimensional Electron Microscopy of Macromolecular Assemblies: Visualization of Biological Molecules in Their Native State
  • [8] Review: Electron crystallography: Present excitement, a nod to the past, anticipating the future
    Glaeser, RM
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 1999, 128 (01) : 3 - 14
  • [9] Specimen charging on thin films with one conducting layer: Discussion of physical principles
    Glaeser, RM
    Downing, KH
    [J]. MICROSCOPY AND MICROANALYSIS, 2004, 10 (06) : 790 - 796
  • [10] RADIATION-DAMAGE IN STAINED CATALASE AT LOW-TEMPERATURE
    GLAESER, RM
    HOBBS, LW
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1975, 103 (MAR): : 209 - 214